Township Authority
Report — 2009
- Date
- Date unknown
- Type
- Report
- Year
- 2009
- File
- PDF · 252 KB
Document text
Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 1,679 words
Maidencreek Township Authority System Identification 1 - PWSID 3060012 Water Report - 2009 Conj Consumer afidence SU AGUA POTABLE INFORMACION IMPORTANTE SOBRE MUY CONTIENE ESTE INFORME TRADUZCALO O HABLE CON ALGUIEN QUE LO ENTIENDA BIEN. In accordance with the Environmental Protection Agency's reporting requirements, we are pleased to provide you with this year's Consumer Confidence Report for the Maidencreek Township Authority. We want to keep you informed about the excellent water goal is, and always has been, to provide to you a dependable supply and services we have delivered to you over the past year. Our g e Well #3 located along g Wesner Road and of drinking g water. Our water source is groundwater wells. The primary water sources are 1 #2 located on June Avenue is a supplemental I water source. All of our Well # 5 located along are Well Burgert Lane. sources drinking water meets federal and state located within Maidencreek Township. We're pleased to report that our requirements. 1 want to learn more, please attend 610-926-4173. We want our valued customers to be informed about their water utility. If f you second Wednesday of meetings. Meetings month at the Maidencreek held on the s every regularly s any of our 1 scheduled are Township Building located at One Road, Blandon. Quarry s for constituents in your drinking g water according to Federal and State The Maidencreek Township Authority routinely monitors monitoring for the period of January 1st to December 3lst, laws. The table contained within this report shows the results of our g water, including bottled drinking amounts of some 2009. All drinking g water, may be reasonably expected to contain at least small a You will find many terms and abbreviations you might not be familiar with contained within the tables of this report. To help you better understand these terms; we've provided the following definitions: Non-Detects (ND) - laboratory analysis indicates that the contaminant is not present at a detectable level. part per million corresponds to one minute in two years or a single Parts per million (ppm) or Milligrams per liter (mgll) - one penny in $10,000. Parts per billion (ppb) or Micrograms per liter - one part per billion corresponds to one minute in 2,o00 years, or a single penny in $10,000,000. Action Level (AL) - the concentration of a contaminant, which, if exceeded, triggers treatment or other requirements which a water system must follow. ing water. Contaminant Level - The "Maximum Allowed" (MCL) is the highest level of a contaminant that is allowed in drink- Maximum ing water. MCL's are set as close to the MCLG's as feasible using the best available treatment technology. Contaminant Level Goal - The "Goal"(MCLG) is the level of a contaminant in drinking g water below which there is Maxrimum no known or expected risk to health. MCLG's allow for a margin of safety. Picocuries Per Liter - Measure of radiation. (pCi/L) Residual Disinfectant Level (MRDL) - The highest level of a disinfectant allowed in drinking There is con- Maximum water. vincing evidence that addition of a disinfectant is necessary f for control of microbial contaminants. Level Goal (MRDLG) - The level of a drinking Residual Disinfectant water disinfectant below which there is no Maximum known or expected risk to health. MRDLGs do not reflect the benefits of the use of disinfectants to control microbial contamination. TEST RESULTS Inorganic Contaminants Range Likely Source of Contamination Level Contaminant (Unit of MCLG Violation MCL Y/N measurement) Detected 1. Nitrate(as Nitrogen) Runoff from fertilizer use; leaching from 9.9 3.6 - 9.9 10 10 septic tanks, sewage; erosion of natural (ppm) deposits. Discharge of drilling 2. Barium (ppm) 0.03410 g waste; discharge from 0278 -.0341 metal refineries; Erosion of natural deposits. 3. Nickel (ppm) Erosion of natural deposits. 0016 .0007 -.0016 .1 Erosion of natural deposits. 4. Chromium (ppm) 0.0 -.0051 005 1 .1 5. Fluoride (ppm) 0.44 Water additive which promotes strong teeth. 0.130 -0.44 (c) Microbiological Contaminants Violation Contaminant Level Range t (Unit of MCL Likely Source of Contamination MCLG measurement) Y/N Detected 1. Total Coliform Naturally present in the environment. 0-5.0% No more than Bacteria 5% positive (positive/negative) sample per month and Copper Lead Contaminants Contaminant Violation of t (Unit of Level Detected Units # of Sites Action MCLG Likely Source of measurement) TT 90th Percentile Level Above AL of Contamination Y/N Value (AL) Total Sites 1. Lead (ppb) 6.4 15 0 out of 20 Corrosion of household Ppb 12/07 (a) plumbing. 2. Copper (udd) 0.352 1.3 1.3 0 out of 20 Corrosion of household ppm 12/07 (b) plumbing. Footnotes: (a) 20 of 20 : samples were less than the Action Level. (b) 20 of 20 samples were less than the Action Level. EPA's MCL for fluoride is 4 ppm. (c) However, our state has set a lower MCL to better protect Human I health. In 2005, to protect and extend the service life of the water storage tanks, the Authority painted both inside and outside of the tanks. Before the tanks were placed back into service, special tests were required by PA DEP to certify the water met accept- able drinking water standards. Total xylene was detected at 9.8 ppb and ethylbenzene was detected at 2.8 ppb. These test results were below the limits promulgated by PA DEP for drinking water. In 2008, the Authority failed to report on a timely basis for Benzo(A)pyrene and Endothall. health benefit is the prevention of tooth decay. . The primary The Authority adds fluoride to its water supply for health benefits. Fluoride is applied at a dosage rate of 0.75 to 1.0 part per million. The State determined this dosage rate to be the best for our climate. do not change frequently. Some of our data, though representative, are more than one year old. Data on Lead, Copper, Gross e year old. The date, which corresponds with the data pre- Alpha, Radium 228, TTHM's and Haloacetic Acid are more than one g water meets or exceeds all Federal and State requirements. We have learned through violations. We're proud that your drinking our monitoring and testing that some constituents have been detected. In addition to the Contaminants listed in the chart above, routinely tests for bacteria. the Maidencreek Township Authority people who drink water emit a form of radiation known as alpha radiation. Some Certain minerals are radioactive and may have an increased risk of getting 226 or 228 in excess of the MCL over many years may who drink water containing radium cancer. g water are subject to potential contamination by constituents that are naturally occurring or man made. sources of drinking All s water, including n be microbes, organic or inorganic chemicals, or radioactive materials. All drinking Those constituents can amounts of some contaminants. The presence of contami- bottled water, may reasonably be expected to contain at least small nants does not necessarily indicate that the water poses a health risk. More information about contaminants and potential health effects can n serve as our community water supply was completed A Source Water Assessment of the Authority's groundwater wells which groundwater sup- (PA DEP). The Assessment has found that are in 2003 by the PA Department of Environmental Protection g and composting facilities, and industrial s (roads and railways), mulching plies are most susceptible to transportation corridors Maidencreek Township Authority office when final copies are received from PA DEP. stringent levels for health effects. To understand the possible health effects described for many regulat- MCL's are set at very lifetime to have a one-in-a- ed constituents, a person would have to drink 2 liters of water every day at the MCL level for a l million chance of having the described health effect. population. Immuno-compromised water than the general be more vulnerable to contaminants in drinking Some people may transplants, people with such as persons persons providers. EPA/CDC guidelines on appropriate means to lessen g water from their health care should seek advice about drinking Water the risk of infection by cryptosporidium and other microbiological contaminants are available from the Safe Drinking Hotline (800-426-4791). work around the clock to provide top . We at Maidencreek Township Authority 1 our office if you I have questions. Please call our customers help protect our water sources, which are the heart of our com- us water to every tap. We ask that all quality munity, our way of life and our children's future. If present, elevated levels of lead can cause serious health problems, especially for pregnant women and young children. Lead in drinking g water is primarily from materials and components associated with service lines and home plumbing. Maidencreek g water, but cannot control the variety of materials used in Township Authority is responsible for providing high quality drinking plumbing components. When your water has been sitting for several hours, you can minimize the potential for lead exposure you are concerned about by flushing your tap for 30 seconds to 2 minutes before using the water for drinking or cooking. If g methods, and steps water, testing e your water tested. Information on lead in drinking lead in your water, you may wish to have Water Hotline or at http://www.epa.gov/safewater/lead. you can take to minimize exposure is available from the Safe Drinking Radioactive Contaminants Likely Source of Contamination MCL Range MCLG Violation Level Contaminant t Unit of Y/N measurement) Detected 15 Erosion of Natural Deposits. 4.5 N/A 4.45-4.54 1. Gross Alpha/Exc Radon & Uranium 5/08 (pCi/l) Erosion of Natural Deposits N/A 2. Radium 228 (pCi/l) 1.35 0-1.35 5/08 Byproducts, Byproduct Precursors, and Disinfectant Residuals Disinfection Likely Source of Contamination MCLG Range MCL Violation Level Contaminant t (Unit of Y/N Detected measurement Byproduct of drinking 80 8.9 5.5-8.9 N/A 1. TTHMs (Total water chlorination. trihalomethanes) 9/08 (ppb) Byproduct of drinking N/A 60 17.6 11.4-17.6 2. Haloacetic Acids water chlorination. (ppb) 9/08 3. Chlorine (ppm) Water additive used to control 0.43 - 0.64 0.64 MRDLG-4 MRDL-4 microbes. Blandon PA 19510 Postal Patron PERMIT NO. 22 BLANDON, PA PAID Blandon, PA 19510-0289 U.S. POSTAGE 289 P.O. Box PRSRT STD Maidencreek Township Authority