Other Township Records

Document — July 28, 2016

Date
July 28, 2016
Type
Document
Year
2016
File
PDF · 2.7 MB

Download original Open in browser

Document text

Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 1,003 words

pennsylvania
DEPARTMENTOFENVIRONMENTAL
PROTECTION
July 28, 2016
Maidencreek Township Supervisors
PO Box 319
Blandon, PA 19510
Re:
Technical Deficiency Letter - Revision
Act 537 Planning
384Evansville Road
DEP CODE NO. A3-06942-127-2
APS ID No.915493, AUTHID No.1137996
Maidencreek Township, Berks County
Ladies and Gentlemen:
The Department of Environmental Protection (DEP) has reviewed the above referenced application and
has identified the following significant technical deficiencies. The items are based on applicable laws and
regulations, and the guidance sets forth DEP's preferred means of satisfying applicable regulatory
requirements.
Technical Deficiencies
1)
The project narrative references water consumption data from a similar retirement facility. That
data was not included in the planning module.
 The primary absorption area defined by soil probes 6/22/7, 6/22/12, 6/22/13, and 6/22/14 was not
delineated on a map with a suitable scale that would allow accurate calculation of the total
suitable square feet.
3)
 The alternate absorption area defined by soil probes 6/22/8, 6/22/9, 6/22/10, and 6/22/11 is not
suitable for sewage disposal due to rock and fractured shale limiting zones at less than 16 inches.
 A plot plan meeting the content requirements of Section G of Component 2, and of suitable scale,
was not submitted with the planning module.
5) Figure 3 shows soil probes 10/26/1, 10/26/2, and 10/26/3 but the reduced scale plot plan shows
soil probes 10/23/1, 10/23/2, and 10/23/3. Please address this discrepancy.
6)
The operation and maintenance of the proposed Department permitted sewage treatment facility
was not adequately addressed in the planning module. Please see Chapter 71, Section 71.72.
7)
The Resolution of Adoption was not on the correct form. A blank copy of the correct form has
been included with the municipality' s copy of the letter.
Additional comments: Specifics of the design of a proposed sewage treatment plant are generally not
reviewed during the planning phase of a project. Nevertheless, a cursory review of the design was
performed and we offer the following for your consideration in designing this system:
Clean Water Program
Southcentral Regional Office I 909 Elmerton Avenue I Harrisburg, PA 17110-8200 I 717.705.4707 1 F 717.705.4760
www.dep.pa.gov

Maidencreek Township
July 28, 2016
1) The design proposes to promote denitrification in the STP's final clarifier. A consequence of this
design is that gas evolution from the denitrification process would result in periodic bulking in
the final clarifier. The resulting solids discharges from these bulking events could potentially
foul the distribution system of the absorption area and result in absorption failure or overflows at
the STP. An alternate method of denitrification should be considered if you choose to pursue this
function of the STP.
2)
There is no evidence to suggest that there is sufficient organic carbon available to facilitate
denitrification downstream of the proposed Aeration Tank in the STP.
3)
The influent nitrogen profile appears to be incorrect as the total nitrogen is less than the sum of
the contributing forms identified in the waste characterization table.
You must submit a response fully addressing each of the significant technical deficiencies set forth above
by September gth or DEP may deny the application. All submitted materials must be submitted by the
municipality, and all deficiency items must be submitted together in one package. A cover letter signed
by the municipal secretary will be accepted by DEP as documentation that the municipality has
determined the resubmission to be consistent with Act 537 sewage planning requirements.
If you believe that any of the stated deficiencies are not significant, instead of submitting a response to
that deficiency, you have the option of asking DEP to make a decision based on the information with
regard to the subject matter of that deficiency that you have already made available. If you choose this
option with regard to any deficiency, you should explain and justify how your current submission satisfies
that deficiency. Please keep in mind that if you fail to respond, your application may be denied.
If you have any questions or concerns regarding the identified deficiencies, please call Michael Morris at
717.705.4793, and refer to DEP Code No. A3-06942-127-2, Application No. 915493 and Authorization
No. 1137996 to discuss your concerns or to schedule a meeting. The meeting must be scheduled within
the period allotted for your reply, unless otherwise extended by DEP. You may also follow your
application through the review process via eFACTS on the Web at:
http://www.ahs2.dep.state.pa.us/eFactsWeb/default.aspx.
Sincerely,
Timothy K. Wagher
Environmental Group Manager
cc:
Moe Farvardin.
Scott McCaffrey, SEO
Berks County Planning Commission

3850-FM-BCW0356
Rev.5/2016
COMMONWEALTHOFPENNSYLVANIA
DEP Code No.
pennsylvania
DEPARTMENTOFENVIRONMENTALPROTECTION
DEPARTMENT OF ENVIRONMENTAL
BUREAUOFCLEANWATER
PROTECTION
RESOLUTIONFORPLANREVISION
FORNEWLANDDEVELOPMENT
RESOLUTIONOFTHE(SUPERVISORS)(COMMISSIONERS)(COUNCILMEN)Of
(TOWNSHIP)(BOROUGH)(CITY),
COUNTY,PENNSYLVANIA(hereinafter“themunicipality").
WHEREAs Section 5 of the Act of January 24, 1966, P.L. 1535, No. 537, known as the Pennsylvania Sewage
Facilities Act, as Amended, and the rules and Regulations of the Pennsylvania Department of Environmental Protection
(DEP) adopted thereunder, Chapter 71 of Title 25 of the Pennsylvania Code, require the municipality to adopt an Official
Sewage Facilities Plan providing for sewage services adequate to prevent contamination of waters of the Commonwealth
and/or environmental health hazards from sewage wastes, and to revise said plan whenever it is necessary to determine
pollution control and water quality management, and
WHEREAS
has proposed the development of a parcel of land identified as
landdeveloper
, and described in the attached Sewage Facilities Planning Module, and
name of subdivision
proposes that such subdivision be served by: (check all that apply),  sewer tap-ins,  sewer extension,  new
treatment facility,  individual onlot systems,  community onlot systems,  spray irrigation,  retaining tanks, 
other, (please specify).
WHEREAS,
finds that the subdivision described in the attached
municipality
ordinances and plans, and to a comprehensive program of pollution control and water quality management.
NOW, THEREFORE, BE IT RESOLVED that the (Supervisors) (Commissioners) (Councilmen) of the (Township)
(Borough) (City) of
hereby adopt and submit to DEP for its approval as a revision to the
attached hereto.
, Secretary,
(Signature)
Township Board of Supervisors (Borough Council) (City Councilmen), hereby certify that the foregoing is a true copy of
adopted,
the Township (Borough) (City) Resolution #
20
Municipal Address:
Seal of
Governing Body
Telephone

Archived from the Maidencreek Township website. Reproduced unaltered; not an official records repository.