Other Township Records
Land Development — October 6, 2016
- Date
- October 6, 2016
- Type
- Land Development
- Year
- 2016
- File
- PDF · 3.8 MB
Document text
Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 1,154 words
MAIDENCREEKTWP.PLANNINGCOMMISSION P.O.BOX 319,BLANDON, PA 19510 October 6, 2016 Maidencreek Township Maidencreek Township Board of Supervisors Zoning Hearing Board PO Box 319 PO Box 319 Blandon, PA 19510 Blandon, PA 19510 Gentlemen, The Maidencreek Township Planning Commission reviewed the Cellco Partnership conditional use and variance application at their meeting on October 5th. The Commission recommends the granting of the conditional use subject to the requested zoning relief being granted and satisfaction of the items brought forth in the Great Valley Consultants review letter dated September 30, 2016, which is attached. The Commission also had no objection to the additional variance is needed to Zoning section 220-48A.(16) to allow more than one tower on a site. They had no objection to this variance if requested. Sincerely, dhelmach Diane Hollenbach Manager Maidencreek Township CC: Kate Durso, Fitzpatrick, Lentz & Bubba P.C. Eugene Orlando, Orlando Law Office Joan London, Kozloff Stoudt P.C. Thomas Unger, Systems Design Engineering, Inc. PHONE:(610)375-8822 GREATVALLEY CONSULTANTS 1-800-733-4821 FAX:(610) 375-8977 75COMMERCEDR/VEWYOMISSING,PA19610-3323 September 30, 2016 Diane Hollenbach, Township Manager Maidencreek Township P. O. Box 319 Blandon, PA 19510 Re: Cellco Partnership d/b/a Verizon Wireless 1 Quarry Road Cell Tower Conditional Use and Variances Request GVC File No. 4026-008 Dear Mrs. Hollenbach: We received for review Plans from Cellco Partnership d/b/a Verizon Wireless titled, "RDG Blandon" submitted by Maser Consulting P.A. The Plans propose the construction of a wireless communications facility/tower on the Maidencreek Township property located at 1 Quarry Road. The location of monopole and related improvements is along the south end of the existing Township building. These Plans were reviewed per the Applicant's request for conditional use approval per the Zoning Ordinance Section 220-48, and for variances from the setback and landscape requirements of Section 220-48(6) and 220-48(16). Please note comments in bold typeface require action by or consideration from the Planning Commission and/or the Board of Supervisors. The remaining comments should be addressed by the applicant or his consultant directly with Township staff or our office. We offer the following comments for your consideration: SUBMISSION INFORMATION 1. Plans for Cellco Partnership d/b/a Verizon Wireless, titled “RDG Blandon", prepared by Maser Consulting P.A., consisting of seven (7) plan sheets as listed: Date Plan No. Description Originated Revised T-1 8/26/16 Title Sheet z-1 8/26/16 Zoning Information Z-2 8/26/16 Compound Layout and Elevation View Z-3 8/26/16 Partial Site Plan A-1 8/26/16 Construction Details A-2 8/26/16 Construction Details A-3 8/26/16 Construction Details 2. Copy of the letter from Fitzpatrick Lentz & Bubba, P.C. dated September 1, 2016 to Maidencreek Township for the Zoning Hearing Board regarding the conditional use and variance requests. 3. Copy of the Supplemental Statement submitted with the September 1, 2016 letter. → Planners → Consultants Engineers Architects surveyors printed on recycled paper GREAT V/ALLEY CONSULTANTS Maidencreek Township September 30, 2016 Planning Commission 4. Copy of the Zoning Hearing Board Notice of Appeal dated September 1, 2016. ZONING ORDINANCE (CODE OF THE TOWNSHIP OF MAIDENCREEK, CHAPTER 220) 1. The communications tower, and associated facilities, is a use permitted by conditional use in the Industrial Zoning District. (Section 220-48.A) 2. The Supplemental Statement affirms the tower will be designed and constructed in accordance with the industry's structural design standards as certified by the registered professional engineer whom sealed the Plans. However, a similar note must be added to the Plans to certify the communication tower's structural capacity and overall safety. (Section 220-48.A(4) 3. Sheet Z-3 indicates a fence seven feet (7') in height will surround the communications tower and associated facilities. The fence must be eight feet (8') in height. (Section 220- 48.A(5)) 4. Landscaping is not proposed to screen the ground-level support structures including the fence. The location of the tower and support structures utilize the south end of the existing Township building so landscaping would not be necessary at that location. Also, the existing communications tower on the property does not have a landscaping screen surrounding the perimeter fence currently. The applicant has requested a variance of the landscape screen of Section 220- 48.A(6). 5. The Supplemental Statement indicates that the design of the tower includes collocation accommodations. It is recommended the Applicant formally acknowledges on the plan that space for Township communication systems shall be made available at no cost to the Township. (Section 220-48.A(9) 6. The tower is only forty-two feet (42') from the southern property line. The setback requirement of the tower from all property lines and existing street right-of-way lines shall be no less than the height of the tower which is one hundred thirty feet (130'). The tower is in compliance with the setback at all other property lines and existing street right-of-way. The proposed setback of this new pole is eight feet (8) further from the southern property line than the existing communications tower. Also included in the setback requirement is the statement of no more than one tower shall be permitted on a site. Provided a communications tower is aiready located on this site, a variance would be necessary for this requirement as well. GREAT VALLEY CONSULTANTS Maidencreek Township September 30, 2016 Planning Commission The applicant has requested a yariance of the setback no less than the height of the tower of Section 220-48.A(16), but must also include in the variance request a second tower be permitted on the site. 7. The Plans must also be prepared in accordance with all applicable sections of the Subdivision and Land Development Ordinance. (Section 220-48.A(18) 8. The existing easement along the access drive is fifteen feet (15') in width. This easement shall be a minimum of twenty feet (20') in width. (Section 220-48.A(20) GENERAL COMMENTS 1. The Plans do not indicate whether the communications tower will be setback no less than the height of the tower, specifically one hundred thirty feet (130'), from the existing Redner building. We recommend that this measurement is shown on the plan and the setback is satisfied. Also, the Planning Commission should note that if the communications tower satisfies the one hundred thirty feet (130') setback from the Redner facility building, it would appear that this setback would extend beyond the side yard setback of the Redner Development Company at this property line. The proposed tower setback may impact future development on the Redner Development Company property. We recommend the Planning Commission Solicitor review this concern. 2. There is a "Gravel Driveway Surfacing" detail on Sheet A-3. It appears the only driveway needed for the proposed tower and facilities will be the paved driveway that services the existing tower. If so, then the gravel driveway detail is unnecessary and can be removed. If not, the detail shall clarify the location on the Plans the detail is applicable. Please do not hesitate to call our office with any questions regarding the above review. Sincerely, SCOTT@. ANDERSON Project Manager SCA:bjc cc: Maidencreek Township Board of Supervisors Eugene Orlando, Esquire Cellco Partnership d/b/a Verizon Wireless Maser Consulting P.A. Catherine E. N. Durso, Fitzpatrick Lentz & Bubba, P.C.