Board of Supervisors

Agenda — January 8, 2020

Date
January 8, 2020
Type
Agenda
Year
2020
File
PDF · 6.8 MB

Download original Open in browser

Document text

Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 2,926 words

MAIDENCREEKTOWNSHIPBOARDOFSUPERVISORS
SEPTEMBER10,2020
ENGINEER'SAGENDA
Subdivision Review Status Checklist
Next Supervisors Meeting October 8,2020
All plans are current.
Subdivision / Zoning / LDP
JoJazSubdivisionPrel./FinalseeSDEreviewItr.Dated8/4/20.
Redner'sQuickshop&CarWashPrel.Plan seeSDEItr.Dated9/2/20.
DavidKopferSketchPlanforRecordseeSDEItr.Dated6/3/20.
Gun Range regulations draft reviewedw/P.C.on 1/8/20 revisions/additions
being made.
Burning Ordinance regulation draft reviewed by P.C. on 9/2/2020 additional
revisions/additions being made.
Projects
StreetProjects2020
ExcelsiorDrive&JuneAve.BOSawarded:
Contract"A"to Recon Construction in the amount of
$206,038.00; work completed 8/20/20.
Contract"B"to New Enterprise Stone & Lime Co.in the amount
of $135,317.50; work is scheduled to begin Sept. 21 (night).
LutzProperty E.WesnerRd.stormwaterissue
Reviewed Walnut Manor&Golden Manor Subdivision Plans(Plans start
in 1987).There is no storm water easement onplans.No notes for
storm water system maintenance on plans.
Inspected site w/Keith S.
Established that headwall is at 2o'6" from centerline & Twp. r/w
is 26'6".
Storm Damage-Follow up from Aug.BoS mtg.
Melrose
Met w/developer, developer Eng. & Atty.
Reviewed repairs to be made & other options for mitigation.
Repairs underway in Basin.
Met w/PennDOTrepresentatives
PennDOT to contact railroad & initiate mtg.
Page 1of 2
I:\Projects/MaidencreekTownship/20-0019-0100/Engineer'sAgendal9.10.20.docx

Inspected GuildinRd.
Clogged storm water pipes @ Park Rd.
Clogged storm waterpipe@ R.R. Crossing
Investigate swale&pipe from Park Rd.toVilla Circle
StormWaterBasins
Putting together plans & Storm Water agreements for each
basin so inspections can be conducted.
SubdivisionImprovementLOC/EscrowRelease
SeeAttached
SewageEnforcementOfficerActivityReport
SeeAttached
Page 2 of 2
I:/Projects/MaidencreekTownship/20-0019-0100)Engineer'sAgendal9.10.20.docx

Most Recent
Letter Date
5/1/2020
8/5/2020
9/2/2020
Review
6/3/2020
Approval conditioned on SDE
Comments
No action taken by PC,
No action taken by PC,
No action taken by PC,
resubmission needed
resubmissionneeded
resubmission needed
reviewletter
Approved
BY BOS
05/14/20
MAIDENCREEKTOWNSHIP,BERKSCOUNTY
(may reflect more
than one extension)
Extension granted
Extension granted
until 11/30/2020
Extension granted
until 12/1/2020
until12/1/2020
Extension
SUBDIVISION STATUS
9/2/2020
I:/ProjectsMaidencreek Township PCISubdivision StatusiSubdivision Status Checklistsl9.2.2020
Period Ends
07/16/20
09/01/20
09/01/20
90-Day
Review
09/01/20
Review Period
04/17/20
06/03/20
06/03/20
90-Day
Begins
06/03/20
Plan Stage
Prelm/Final
Prelm/Final
Sketch Plan
Prelm Plan
for Record
Plan
Plan
APPROVED /PENDINGPLANS:
Redner's Quickshop and Car Wash
David Kopfer Subdivision
CURRENT PLANS:
Schick Dental Office
Jojaz Subdivision
Project Name
No.

SYSTEMSDESIGN
"A Passion for Engineering Excellence"
SDE
ENGINEERING,INC
sdei.net
September2,2020
DianeHollenbach,TownshipManager
MaidencreekTownship
1 Quarry Road
Blandon,PA19510
Re:
Redner's Quickshop and Car Wash
PreliminaryPlanReview#3
Ms. Hollenbach:
Systems Design Engineering, Inc. is in receipt of a Preliminary Plan entitled "Redner's Quickshop
and Car Wash." The site has three (3) access points; two on Allentown Pike (US Route 0222) and
another on Lake Shore Drive (PA Route 0073). The proposal would resuit in gas pumps, a
convenience store, and car wash. The Plan was prepared by Bogia Engineering, Inc. The
submission consisted of response letters to SDE's August letter, a Stormwater Management
report (including supplemental computations) and the following:
Cover Sheet
Sheet 1 of 11
Dated5/20/2020,Rev8/19/2020
Existing Conditions Plan
Sheet 2 of 11
Dated 5/20/2020, Rev 8/17/2020
Grading and Utility Plan
Sheet 3 of 11
Dated 5/20/2020, Rev 8/19/2020
Details Plan
Sheet4of11
Dated 5/20/2020, Rev 8/19/2020
Details
Sheet 5of11
Dated 5/20/2020, Rev 8/19/2020
Landscaping Plan
Sheet 6 of 11
Dated 5/20/2020, Rev 8/19/2020
Lighting Plan
Sheet 7of 11
Dated 5/20/2020, Rev 8/19/2020
E&SPlan
Sheet 8 of 11
Dated5/20/2020,Rev8/19/2020
E&SPlanDetails
Sheet 9of 11
Dated5/20/2020,Rev8/19/2020
Drainage Area
Sheet 10 of 11
Dated 5/20/2020,Rev8/19/2020
Truck Turn
Sheet 11of 11
Dated5/20/2020,Rev8/19/2020
BACKGROUND:
The purpose of the plan is to establish a gas station, car wash and convenience store on parcels
zoned C-1 Local Commercial. The subject site consists of three (3) neighboring parcels that total
1.75 acres in size. The site is to be served with public water and sewer. The site previously
included a gas station and Top Star convenience store. The current proposal would utilize the
I:\Projects(Maidencreek TownshipPC/20-0024-0717Redner's QuickshopandCarWash/Redner's Prel PianRev#3.docx
1032 James Drive, Leesport, PA 19533.P: 610.916.8500. F: 610.916.8501
SchuylkillHaven,PAP:570.385.5549
Boyertown,PA.P:610.369.1319

MaidencreekTownshipPlanning Commission
September2,2020
Re:
Redner's Quickshopand Carwash
Page 2of9
PreliminaryPlanReview#3
existing building, while gas pumps would be moved to the southwest side of the site and a car
wash would be constructed. The existing driveway onto Rt. 222 will be removed and a new
driveway constructed tothe south.
The applicant is also in the process of seeking zoning relief from the Maidencreek Township
Zoning Hearing Board.
REVIEW:
This letter presents comments on the third review of the submitted Preliminary Plan.
ZONING:
The subject site is iocated in the C-1 Local Commercial Zoning District.
1. The first review did not interpret the proposed car wash as an accessory use. The car
wash is interpreted as a use permitted by Special Exception.
8/4/2020.
2.Per$220-62, Sign Regulations
 A previous sign at the corner of Allentown Pike and Lake Shore Drive was
removed. However, new sign details are not provided.
oThe Applicant should put sign details on the plan and demonstrate
compliancewithSection$220-62.
1. Addressed. The applicant stated that sign regulations would be in
compliance. Details for traffic signage was provided. Details for
business signage is not provided.
a. The applicant stated via Note 15 that all signage would
comply with the appropriate Township Ordinanceand
further stated that a signage packet would be submitted
outside the land development submission. A separate
zoning permit will be required.
SDE

Maidencreek Township Planning Commission
September2,2020
Re:
Redner'sQuickshopandCarwash
Page3of9
PreliminaryPlanReview#3
3. Special Exceptions
Section $220-65 states special exception requirements for car washes:
Car washes are permitted only in an enclosed building that must be at least
1oo feet from residential districts and right-of-way intersections.
Additionally, sufficient space must be provided for at least ten (1o) stacked
vehicle spaces.
Addressed. A special exception to allow the car wash use was
approved on 8/4/2020. A variance was granted on 8/4/2020 to
allow six (6) stacking spaces, rather than ten (10).
LIGHTINGSTANDARDS:
1.Per$186-48, LightingPlanSubmission
Lighting plans are required in the Preliminary Plan stage of all development plan
reviews.
Thefollowing are comments on theupdated Lighting Plan by SDE's
electrical designer:
The Type 'A' fixture in the Luminaire Schedule' is not a 'cut-off' type
as defined by I.E.S. and therefore does not comply with Section
g186-46oftheTownshipZoningOrdinance.
The Type 'B' fixture spec sheet is not included on the drawing.
Please clarify if both Type'A'and'B'wall packs are used on the
building simultaneously or if one type used for after-hours security
only.
SALDO:
1.Per$190-15,PreliminaryPlanRequirements
Per Subsection C, the plan shall be sealed by the professional responsibie for the
plan.
Partially Addressed. The applicant stated that the plans will be sealed by a
Professional Engineer at the time of Final plan approval.
SDE

MaidencreekTownshipPlanningCommission
September 2, 2020
Re:
Redner's Quickshopand Carwash
Page 4 of 9
PreliminaryPlanReview#3
2.Per$190-34Sidewalks
Sidewalks may be required for commercial developments by the Board of
Supervisors.
O Addressed. Note 16 states that the lot owner will be responsible for
sidewalk construction if deemed necessary bythe Township Supervisors.
3. Per $190-44, Landscaping
The selected species--Prunus serrulate (Kwanzan Cherry)and Juniperus Chinesis
(Seagreen Juniper) - are not included on the Townships recommended list.
 SDE's landscape architect stated that the chosen species are acceptable.
However, the location of existing vegetation should also be provided prior
to Final Pian approval.
STORMWATER MANAGEMENT:
1.Per §182-11, Erosion and Sediment Control -The Erosion &Sediment Control Plan should
be submitted to the Berks County Conservation District for review and approval. A copy
of the approval letter should be submitted to the Township priorto Final Plan approval.
2. Per §182-16.A.(2), Stormwater Management Districts -The computations indicate that
the post-development runoff to Point of Interest 2 (POl-2) does not meet the reduced
runoff rates required by the ordinance. It is unclear at this time whether the proposed
detention basin will adequately reduce the runoff rates to POl-3 because of revisions to
both the pre-development runoff and post-development runoff computations noted in
comments under Miscellaneous Stormwater Management Plan and Computations
Comments.
3. Per S182-17.D.(3), Design Criteria for Stormwater Management and Conveyance BMPs 
Notes describing the required pipe specifications for"sLCPp" should be provided on the
plans, including material and watertight joints.
4. Per $182-22.B.(22) and $182-22.E.(2)(d), Drainage Plan Contents -- The Certificate of
Landowner should be revised to include the requirements of both of these sections.
5.PerS182-23,PlanSubmission-AcopyofthePennDOTHOPplans shouldbesubmittedto
theTownship concurrently with the submission to PennDOT to allow coordination with
the SALDO review. A copy of the HOP drawings should be submitted to the Township
SDE

MaidencreekTownshipPlanningCommission
September2, 2020
Re:
Redner's Quickshopand Carwash
Page5of9
PreliminaryPlanReview#3
when theapplication is submittedtoPennDOTtoallow coordinationwith the SALDO
review.Aiso see Comment 3undertheGrading&Utility Plan comments.
6.Per S182-24.F--The proposed storm sewer connections to the proposed inlet located in
the SR 0222 right-of-way, as well as the driveway modifications, will require a PennDOT
Highway Occupancy Permit. A copy of the approved HOP(s) should be submitted to the
TownshippriortoFinalPlanapproval.
7. Per §182-30, Performance Guarantee -- A financial guarantee should be provided for the
proposed stormwater management controls prior to Final Plan approval.
8. Per $182-32 and $182-34, Operations and Maintenance Agreement for Privately Owned
Stormwater Controls and BMPs-The Stormwater Management Controls and Best
Management Practices Operations and Maintenance Agreement in Appendix A of the
Stormwater Management Ordinance shouid be submitted for review and approval by the
Township priorto Final Planapproval.
MISCELLANEOUS STORMWATER MANAGEMENT PLAN AND COMPUTATIONS COMMENTS:
1. The post-development runoff CN for lawn areas in all the Disturbed drainage areas should
be 65 instead of 58, per Table B-2. This CN may also be used for the Undisturbed and
Offsite lawn areas for pre- and post-development conditions.
2. The existing conditions impervious area used in the computations is significantly higher
than the previous submission and the area measured off the Existing Conditions Plan. The
total existing impervious area should be approximately 0.40 acres instead of 0.67 acres.
3. The allowable post-development site runoff to POl-3 for the 2-yr storm should be
computed by adding the peak 1-yr disturbed DA-C area flow and the peak 2-yr
undisturbed DA-C and Offsite Bypass-2 flows (since the Tc is the same for all the drainage
areas). The flows must be added manually because the computer model cannot add
hydrographs from different storm frequencies. The allowable flows for all other storm
events should be computed in the same way.
4. The detention basin outlet pipe length and slope used for the basin stage/discharge
computations should be revised to match the storm sewer computations.
5. The emergency spillway invert (343.30) shouid be set above the adjacent Rt. 222 curb
elevation (approximately 343.55 through 343.65 at the current location). Based on the
grate elevation noted for the proposed inlet at POl 3, the top of curb elevation is 343.34.
SDE

MaidencreekTownshipPlanningCommission
September2,2020
Re:
Redner'sQuickshopandCarwash
Page 6of9
PreliminaryPlanReview#3
6. The swale design computations should be based on a design flow that matches the 25-yr
flow to Es-1-1 from the storm sewer computations. In addition, the computations are
based on a 7' bottom width, but the grading plan reflects a 2' bottom width.
COMMENTS ON THE GRADING & UTILITY PLAN:
1. At a minimum, the starting invert elevations for Downspout Ds-1 and Ds-6 should be
noted to provide the contractor with sufficient information to construct the rainwater
conductor system.
2. The outfall of DS-6 should be moved lower into the basin assuming the invert will be
approximately342.50.
3. in order to provide the drainage area boundary shown for Bypass-2, the 344 contour must
be revised to reflect a berm at the boundary location, and bottom of curb/paving spot
elevations should be provide at the two curb radi to ensure runoff does not run down the
driveway to Rt. 222. The 344.20 spot elevation must be raised if runoff is to flow toward
theother344.20intheflowline.
The HOP driveway profile must agree with the grading revisions noted above.
4. The proposed 345 contour should be provided to define the Swale #1 grading. In
addition, it appears that the proposed grading at the upper end of the swale will require
grading on the adjacent property. The proposed 348 and 350 contours should be shown.
5. The proposed 346.50 spot elevation at the northeast corner of the fueling area canopy is
almost 2' lower than the existing paving grade at this location. Additional proposed
grading should be shown to tie this elevation back into the existing driveway grades. Also,
this elevation appears to be too low with respect to the trash enclosure elevation and the
existing curb immediately to the east of the fueling area. The existing bottom of curb
elevation appears to be at least 15" higher than the proposed spot elevation.
6. Additional proposed contours and spot elevations should be provided upslope of Inlet I-2-
1. This area must be regraded to ensure all runoff from drainage area Bypass-2 is directed
into inlet I-2-1, as assumed by the drainage area boundary. In addition, this inlet should
be located in a sag in order to prevent bypass flow from reaching POl-3. if the design
allows for bypass flows, these flows must be accounted for in the total post-development
runoff to POl-3.

MaidencreekTownshipPlanningCommission
September2,2020
Re:
Redner'sQuickshopandCarwash
Page7of9
PreliminaryPlanReview#3
7. Some of the proposed storm sewer system along the new Rt. 222 curb line is now noted
as 18" CMP; however, it is our understanding that this system is RCP. The designer should
verifythe correct pipe material.
8. The proposed p-1 invert in the Rt. 222 inlet should be noted.
COMMENTS ON THE STORM SEWER AND RAINWATER CONDUCTOR DESIGN:
1. The longitudinal slope and cross-slope values used for I-2-1 are not verifiable from the
grading plan. The computations indicate that a significant portion of the flow to the inlet
is not captured (approx. 50%) and will drain to POl-3. As noted previously, this bypass
flow increases the post-development flow to POl-3.
2. Computations for the rainwater conductor system should be provided. The plan notes 3"
diameter pipes for DS-1 through DS-4; however, at 1% slope, a 3" pipe only has capacity
forlessthan 1,100SFof roofarea.
MISCELLANEOUSDRAFTINGCOMMENTS:
1. The Vegetated Swale detail should reflect the parameters used in the swale design
computations,includingthetotal depth and bottom width.
2. A detail is provided for a check dam in the swalie; however, the location is not shown on
theplan and thepurpose of the check dam is unclear.
3. The Top of Clay Liner elevation shouid be noted on the Detention Basin Cross-Section.
The clay core should be removed if it is not being provided due to instailing the clay liner.
4.The outlet elevation, BOE, in the Detention Basin Cross-Section should be revised.
5. The Typical Emergency Spillway detail should note the erosion control blanket material.
In addition, the elevations noted for the crest and top of berm should be revised.
6. The height of the trash rack shouid be revised on the Orifice Plate detail to conform to the
dimensions of the outlet structure orifices and bottom of the top unit.
7. The TG, upper 3" orifice and outlet pipe elevation/inverts should be revised on the Basin 1
Outlet Structure detail.
8.The OS-1-1 TG elevation noted on the Grading & Utility Plan should be revised.
SDE

MaidencreekTownshipPlanningCommission
September2,2020
Re:
Redner'sQuickshopandCarwash
Page8of9
PreliminaryPlanReview#3
9. It appears that the plan shows 33 proposed parking spaces. Whereas, it is stated on sheet
1 that there are 35 proposed spaces. Clarification should be provided or the plan should
be amended to reflect the correct number of provided spaces.
MISCELLANEOUS:
1. MTA approval is required. The plans should be submitted to the Maidencreek Township
Authority and an approved review letter should be provided to the Township upon
receipt.
Partially addressed. The plan was submitted to MTA. Receipt of approval by the
MTA should be submitted to the Township office and to SDE.
2. An approved PennDOT Highway Occupancy Permit should be provided for access points
alongAllentownPike
Outstanding. An approved HOp has not been provided. The applicant stated that
it will be provided once received.
3. Curb Radii
The applicant should explain or amend the 2-foot curb exit radius at the
northeastern access point to Us Route 0222.
The 2-foot curb radii have been amended to 5 feet. These will need to be
reviewed and approved by PennDOT as part of the HOP approval.
1. Partially addressed. The applicant stated that an approved HOp
will be provided once received.
SDE

MaidencreekTownshipPlanningCommission
September2,2020
Re:
Redner'sQuickshopandCarwash
Page 9of 9
PreliminaryPlanReview#3
If you should have any questions or comments, please do not hesitate to contact our office.
Sincerely,
SYSTEMSDESIGNENGINEERING,INC.
PhilipJ.Ashear
Township Planning Consultant
Cc:
MaidencreekTownshipPlanningCommissioners
DianeHollenbach/TownshipManager
Nicole Plank, Esq.
Bogia Engineering, Inc.
SDE

SUMMARY
IMPROVEMENTAGREEMENTSINVOICES
APPROVEDFORPAYMENT
MAIDENCREEKTOWNSHIPBOARDOFSUPERVISORS
SEPTEMBER4,2020
DATE OFINVOICE/PAYEE
INVOICE NO
AMOUNT
1.Melrose Place Insp.
101673
$1,068.99
8/31/20 Maidencreek Twp. -- Re: SDE, Inc.
AMOUNTDUE
$1,068.99
2. (
GsP Properties,LLC
8/31.20 Maidencreek Twp. -- Re: SDE, Inc.
101674
$503.06
AMOUNTDUE
$503.06
TOTALAMOUNTDUE
$1.572.05
I:\Projects\Maidencreek Township/mprovement Agreement Summaries/202019.4.20.doc

MAIDENCREEKTOWNSHIP
SEOACTIVITYREPORT
July,2020
Fee Paid to
Date By
SDE #
ADD.#
Applicant/Activity
Applicant
Billed/Paid
Chk #
281BlandonRoad
7/19/19-Replacementsepticsystemapplication.Testingwas
performed byprevious SEO. Verifytest site.Send idemntification
form to applicant. Septic system permit cannot be issued until the
19-0019-0479
Z176966
notarized indemnification is received by SEO.
9/4/19 -Process application and verification of prior testing for new
septic system. Review design/issue permit
No update
724.00
Paid
1002
65 Troxel Rd.
19-0019-0480
Z203635
10/7/19-Reviewdesign/issuepermit for newsystem
No update
585.00
Paid
122
1142PleasantHill Road-Ownerwantstosubdivideanother lotoff
of the farm.
2/17/20-Schedule testingandnotifyPADEP.
3/5/20 -Probes for primary and replacement system on new lot
and replacement area for existing lot.
20-0019-0481
3/6/20 - Conduct percolation testing for primary and replacement
Subdivision
system on newlot.
3/31/20-Completesoilreports,sendtoconsultant
6/2/20-Rec incomplete planningmodule.Sendletterto
consultant.
6/9/20-Communicationsw/PhilAshearandPADEPre:nitrate
easementrequirements.
$1,608.00
Paid
114
107oMaidencreek Road-Thepropertydidn'tpass thereal estate
inspection. Replacement septic system testing is necessary.
20-0019-0482
Z215216
3/17/20-Conduct soil probes.Dig/presoak perc holes.
3/18/20-Performpercolationtest.
No update
692.00
Paid
872ParkRd-Replacementsystem
5/13/20-Processapplication
20-0019-0485
5/14/20-Observeprobes
Z210426
5/15/20 -Perform percolation test
5/18/20 Soil report and send to deigner
6/11/20 -Review design. Fees due before permit can be issued.
570.00
Paid
50873
185OrchardRoad-Replacementsystem
5/20/20Probestesting
5/21/20PercTest
5/21/20soil&perc reportwriteup
20-0019-0486
Z207852
5/25/20scanned soil &perc reportand email todesigner
7/24/20 -Review design/issue permit to install system.
7/28/20-ScarificationinspectionPASSED
1264&
8/4/20-Pressure test inspection PASSED
$1,245.00
Paid
1269
20-0019-0300
Misc Admin
General Work
Cc:T.Unger 2 copies
SEO Desk
projects/maidencreek/20-0019-0300/seoactivity

Archived from the Maidencreek Township website. Reproduced unaltered; not an official records repository.