Other Township Records

Pool and Hot Tub Packet

Date
Date unknown
Type
Document
Year
2024
File
PDF · 8.0 MB

Download original Open in browser

Document text

Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 3,675 words

APPENDIX G
SWIMMING POOLS,SPAS ANDHOTTUBS
(The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.)
SECTION AG101
mm) deep. This includes in-ground, above-ground and
GENERAL
On-ground swimming pools, hot tubs and spas.
AG101.1 General.The provisions of this appendix shall con-
SWIMMING POOL, INDOOR. A swimming pool which is
trol the design and construction of swimming-pools, spas and
totally contained within a structure and surrounded on all four
hot tubs installed in or on the lot of a one- or two-family dwell-
sides by the walls of the enclosing structure.
ing.
SWIMMING POOL, OUTDOOR. Any swimming pool
AG101.2 Pools in flood hazard areas.Pools that are located
which is not an indoor pool.
in flood hazard areas established by Table R301.2(1), includ-
ing above-ground pools, on-ground pools and in-ground pools
that involve placement of fill, shall comply with Sections
SECTIONAG103
AG101.2.1 0r AG101.2.2.
SWIMMING POOLS
Exception: Pools located in riverine flood hazard areas
AG103.1 In-ground pools. In-ground pools shall be designed
which are outside of designated floodways.
and constructed in conformance with ANSINSPI-5 as listed in
AG101.2.1 Pools located in designated floodways. Where
Section AG108..
pools are located in designated floodways, documentation
AG103.2 Above-ground and on-ground pools. Above-
shall be submitted to the building oficial, which demon-
ground and on-ground pools shall be designed and constructed
strates that the construction'of the pool will not increase the
in conformance with ANSINSPI-4 as listed in Section AG108.
design flood elevation at any point within the jurisdiction.
AG103.3 Pools in flood hazard areas. In flood hazard areas
AG101.2.2 Pools located where floodways have not been
established by Table R301.2(1), pools in coastal high hazard
 designated. Where pools are located where design flood
areas shall be designed and constructed in conformance with
elevations are specified but floodways have not been desig-
ASCE 24.
nated, the applicant shall provide a floodway analysis that
demonstrates that the proposed pool will not increase the
design flood elevation more than 1 foot (305 mm) at any
SECTIONAG104
point within the jurisdiction.
SPASANDHOTTUBS
AG104.1 Permanently installed spas and hot tubs. Perma-
nently installed spas and hot tubs shall be designed and con-
SECTIONAG102
structed in conformance with ANSINSPI-3 as listed in Section
DEFINITIONS
AG108.
AG102.1 General. For the purposes of these requirements, the
AG104.2 Portable spas and hot tubs. Portable spas and hot
terms used shall be defined as follows and as set forth in Chap-
tubs shall be designed and constructed in conformance with
ter 2.
ANSI/NSPI-6 as listed in Section AG108.
ABOVE-GROUND/ON-GROUND' POOL. See “Swim--
ming pool."
SECTIONAG105
BARRIER. A fence, wall, building wall or combination
BARRIERREQUIREMENTS
thereof which completely surrounds the swimming pool and
AG105.1 Application. The provisions of this chapter shall
obstructs access to the swimming pool.
control the design of bariers for residential swimming pools,
HOT TUB. See “Swimming pool."
spas and hot .tubs. These design controls are.intended to pro-
IN-GROUND POOL. See "Swimming pool."
vide protection. against potential drownings and near-
drownings by restricting access to swimming:pools, spas and
RESIDENTIAL. That which is situated on the premises of a
hot tubs.
detached one- or.two-family dwelling or a one-family town-
AG105:2 Outdoor swimming pool. An outdoor swimming
house not more than three stories in height.
pool, including an. in-ground, above-ground or on-ground
SPA, NONPORTABLE. See "Swimming pool"
pool, hot tub or spa shall be surrounded by a barrier which shall
SPA, PORTABLE. A nonpermanent structure intended for
comply with the following:
recreational bathing, in which all controls, water-heating and
1. The top of the barrier shall be at least 48 inches (1219
water-circulating equipment arean integral part of the product.
mm) above grade measured on the side of the barier
SWIMMING POOL. Any structure intended for swimming
which faces away from the swimming pool. The maxi-
or recreational bathing that contains water over 24 inches (610
mum vertical clearance between grade and the bottom of

APPENDIX G
the barrier shall be 2 inches (51 mm) measured on the
8.2. The gate and barrier shall have no opening larger
side of the barier which faces away from the swimming
than %, inch (12.7 mm) within 18 inches (457
pool. Where the top of the pool structure is above grade,
mm) of the release mechanism.
such as an above-ground pool, the barrier may be at
9. Where a wall of a dwelling serves as part of the barrier,
ground level, such as the pool structure, or mounted on
one of the following conditions shall be met:
top of the pool structure. Where the barrier is mounted on
top of the pool structure,themaximumverticalclearance
9.1. The pool shall be equipped with a powered safety
between the top of the pool structure and the bottom of
cover in compliance with ASTM F 1346: or
the barrier shall be 4 inches (102 mm).
9.2. Doors with direct access to the pool through that
2. Openings in the barrier shall not allow passage of a
wall shall be equipped with an alarm which pro-
4-inch-diameter (102 mm) sphere.
duces an audible waming when the door and/or
its screen, if present, are opened. The alarm shall
3. Solid barriers which do not have openings, such as a
be listed and labeled in accordance with UL
masonry or stone wall, shall not contain indentations or
2017. The deactivation switch(es) shall be
protrusions except for normal construction tolerances
located at least 54 inches (1372 mm) above the
and tooled masonry joints.
threshold of the door, or
4. Where the barrieris composed of horizontal and vertical
9.3. Other means .of protection, such as self-closing
members and the.distance between the tops of the hori-
zontal members is less than 45 inches (1143 mm), the
doors with self-latching 'devices, which are
horizontal members shall be located on the swimming
approved by the goveming body, shall be accept-
able as long as the degree of protection afforded
pool side of the fence. Spacing between vertical mem-
is not less than the protection afforded by Item
bers shall not exceed 1/, inches (44 mm) in width.
9.1 or 9.2 described above.
Where there are decorative cutouts within vertical mem-
bers, spacing within the cutouts shall not exceed 1/4
10. Where an above-ground pool structure is used as a bar-
inches (44 mm) in width.
rier or where the barrier is mounted on top of the pool
structure, and the means of access is a ladder or steps:
5. Where the barrieris composed of horizontal and vertical
members and the distance between the tops of the hori-
10.1. The ladder or steps shall be capable of being
zontal members is45 inches (1143 mm) or more, spacing
secured, locked or removed to prevent access;
between vertical members shall not exceed 4 inches (102
mm). Where there are decorative cutouts within vertical
10.2. The ladder or steps shall be surrounded by a
members, spacing within the cutouts shall not exceed 13/
. barrier which meets the requirements of Sec-
inches (44 mm) in width.
tion AG105.2, Items 1 through 9. When the lad-
6. Maximum mesh size for chain link fences shall be a
der or steps are secured, locked or removed, any
2'/-inch (57 mm) square unless the fence has slats fas-
opening created shall not allow the passage of a
tened at the top or the bottom which reduce the openings
4-inch-diameter (102 mm) sphere.
to not more than 13/, inches (44 mm).
AG105.3 Indoor swimming pool. Walls surrounding an
7. Where the barrier is composed of diagonal members,
indoor swimming pool shall comply with Section AG105.2,
such as a lattice fence, the maximum opening formed by
Item 9.
the diagonal members shall not be more than 1/, inches
(44 mm).
AG105.4 Prohibited locations. Barriers shall be located to
prohibit permanent structures, equipment or similar objects
8. Access gates shall comply with the requirements of Sec-
tion AG105.2, Items I through 7, and shall be equipped
from being used to climb them.
to accommodate a locking 'device. Pedestrian access
AG105.5 Barrier exceptions. Spas or hot tubs with a safety
gates shall open outward away from the pool and shall be
cover which complies with ASTM F 1346, as listed in Section
self-closing and have.a self-latching device. Gates other
AG107, shall be exempt from the provisions of this appendix.
than pedestrian access gates shall have a self-latching
device.. Where the release mechanism of the self-latch-
ing device is located less than 54 inches (1372 mm) from
the bottom of the gate,the release mechanism and open-
SECTION AG106
ings shall comply with the following:
ENTRAPMENTPROTECTIONFORSWIMMING
POOL AND SPASUCTION'OUTLETS
8.1. The release mechanism shall be located on the
" pool side of the gate at least 3 inches (76 mm)
AG106.1 General. Suction outlets shall be designed and
below the:topof the gate; and
installed in accordance with ANSVAPSP-7.

Barrens
The Consumer Producl Safety Commission has reported thal drowning is the
I leading causc of accidental death in and around the home for children under
the age or 5 ye ars in California. Arizona, and Florida. Seventy five peicent of the
children involved in swimming pool submersion or drowning accidents are
 Hard wired power req'd plus battery backup .. ...
between 1 and 3 years old. Victims had been missing for five minutes or less
.313
wtien they were found in the pool drowned or submerged. Other bodies of water.
 Min one detector each story & basement
such as fish ponds and fountains, have the samerpotential drowning hazards
..F81 (313
as pools.
 Battery powered OK for remodel
General
IRC
UBC
 Compliance req'd for work (>$1.00jrequiring permit or
1313
 Applies lo all pools or spas >24in deep
-(AG102.1]
(420)
when aterations create an additional bedroom . .
Fence min 4Bin high
.F80 (AG105.2]
(421.1#1)
..313.1
 Gap under fence max 2in above grade (4in i concrete]F80 [AG105.2]
(421.1#1)
 Bottom max 4in above pool structure when mounted
ontopofpool.
[AG105.2]
(421.1#1)
 Max opening size must prevent passage
of 4in sphere
. .F80 [AG105.2]
(421.1#1)
Fig. 81
 Difficuft to climb over (no ladder type rails) .. . . . .F80 [AG105.2]
(421.11)
Smoke-Dcl
 Chain link max 1/asq.in mesh unless flled with slats [AG105.2]
(/a)
 Gate lockable, self-cosing. open away from pool .F80 [AG105.2]
(421.1#4)
 If lalch <54in high: Must be poolside & min
3in below top
..F80 [AG105.2]
(421.1#4)
Top story
 No openings >hin within 18in of latch .
{(AG105.2]
(421.1#4)
 Doors & screens with direct poal access req. alarm
Ha
audible for 30 seconds throughout house .
.{AG105.2]
ad,
(421.1#5X
Bedroom
ber
 Alarm control min 54in high, must resel
automaticalyExC
[AG105.2]
(421145X)
Doors from interior w/self close and release 254in
above floor
[AG105.2]
(421.1#5X
 if above ground pool ladder or steps must be
Ist story
lockableorbarrier
.{AG105.2]
(421.1#6)
 Safety glazing req'd for glass encosing pool
..F80 [308.4]
(2406.4)
Basement
Fig.80 Pool Bamiers
No opening 'h"
within 18"of gate latch
& latch must be pool.slde f
lessthan 54"higt
nanspecton
Paperwork-special inspection reports on fic.....119 (109)
 Floor finishes that alfect stairs or landings must
be complete
(109.1
 Appliances and futures nust be in iace..
.(109.1
 Exterior pipe pencurations nust be calk:ed
.{2606
 Wood siding and Lrim min 6in from earth
. {323.
 Smoke detectors installed and opcralional .
..FB1 (313
Any glass
 Exterior doors and windows must be weather tight . [1 102.1.1
Min.
In fence
 Building address numbers legble from slreel .
48"
.(321
Max. :
must be safety
from grade T
glass or plastic.
Gate' swings
Mu. 4"
SpecialinspectlonRepone
ourtward
opening
S.i. reports due before final inspction
Requlred
Pilings,drilled plers & caissons
Heatreq'dinhabitablerooms68'(70131l above floor
(303.8]
(310.11)
Bolts in concrete
Minoneroom2120sqft
(304.1)
(310.6.2)
seiawaime
Habitable rooms exckitchensmin70sqft&
Glu-Lam certificate
min dimension 7ft
.{(304.2.3]
(310.6.2.3)
 Ceiling height habitable spaces min 7fht (7ft 6in)
..(305.1)
(310.6.1)
High-surengih bolting
 Kitchnens. bathis. & hallways min ceilinc hcighit 7ft ExC . . {305.1]
(310.G.1)
Gft Bin OK in baths ovcr fixture & (ronl clearancc arca . . (305.1]
nCcilinr elt unfinielne
TEIFS
inChD.

Municipality:
County:
Permit No.:
Version 01
ZONING PERMIT APPLICATION
A.LOCATIONANDOWNERSHIPOFPROPOSEDWORKORIMPROVEMENT
Street and Number:
UPI #:
Deed Owner:
Deed Reference:
Owner's Address:
Phone #:
Zoning District (as shown on ZONING MAP):
Present Tenant:
Has owner consented to proposed work?:Yes
No
B.PRESENT USEOFLAND
RESIDENTIAL
COMMERCIAL
Present use of structure:
Number of Families:
Present Building (Description):
Present Use of Land:
Is any portion of the property located in a FEMA Flood Plain?
Yes
No
Is the site located within a Historic District?
Yes
No
C. PROPOSEDWORKOR IMPROVEMENT (Check One)
NewConstruction
Addition
InteriorAlteration
ExteriorAlteration
Fence
Accessory Structure
Deck
 Sign (Sign application and drawing of sign must be submitted with this application.)
Change inUse. PresentUse:
Proposed Use:
Describe proposed work:
Is the proposed structure or use located in FEMA designated flood plain? Yes
No
D. PROJECT DIMENSIONS
PLOT DIMENSIONS
BUILDINGSETBACKS
BUILDINGDIMENSIONS
Frontage
ft.
Front
ft.
Width
ft.
ft.
Side A
Depth
ft.
Depth
ft.
Side B
ft.
Height
Area
_sq. ft.
ft.
Rear
Irregular plot
ft.
Stories
SIGNAGE:
Type:
Number:
Size:
sq. ft.
E.APPLICATION
Application is hereby made for a permit to erect or alter a structure which shall be located as shown on diagram on reverse side of
this sheet and/or to use the premises for the purposes described herewith. The information which follows, together with location
diagram, is made part of this application be the undersigned. It is understood and agreed by this applicant that any error,
misstatement or misrepresentation of material fact, either with or without intention on the part of this applicant, such as might or
would operate to cause a refusal of this application, or any change in the location, size or use of structure or land made subsequent
to the issuance of this permit, without approval of the Zoning Office, shall constitute sufficient grounds for the revocation of this
permit.
Name of Applicant:
Address of Applicant:
Owner, Lessee or authorized agent for owner of subject property:
Applicant's Signature:
Date:
No
Fee attached:Yes
Check No.:
Systems Design Engineering, Inc.
1032 James Drive
Leesport, PA 19533
Phone610-916-8500;Fax610-916-8501

Municipality:
County:
Permit No.:
Version 01
F. PLOT PLAN SKETCH
NOTE: The property owner and applicant assumes the responsibility of locating all property lines, setback lines, easements, rights-of-
way, flood areas, etc. Property owner and applicant shall not construct or erect structures or encroach into the Municipality's
right-of-ways.
G. REFERENCES (OFFICIAL USE ONLY)
Block Plan No.:
Certificate of Occupancy No.:
Issued:
Plan is attached.: Yes
Diagram is shownon reversesideofthis sheet.:Yes
No
H. APPLICATION AND DATES OF ACTION TAKEN_(OFFICAL USE ONLY)
Application approved: Yes
No Date:
Zoning Official Signature:
If denied, Reason for Denial of Application:
NOTE: The applicant has the right to appeal the denial of this application to the Municipality's Zoning Board within 30 days
from the date of denial pursuant to procedures set forth in the Pennsylvania Municipalities Planning Code, as amended.
Date:
Applied to Board of Adjustment:
Appeal:Yes No Hearing No.:
Special Use of Application:Yes
Denied
Board'sDecision:Granted
Date:
Order:
Systems Design Engineering, Inc.
1032 James Drive
Leesport, PA 19533
Phone610-916-8500;Fax610-916-8501

Municipality:
County:
Permit No.:
BUILDING CODE PERMIT APPLICATION
A.LOCATIONOFPROPOSEDWORKORIMPROVEMENT
Site Address:
Tax Parcel #:
Sub-Division:
Lot No.:
Phase:
Section:
Owner:
Phone #:
Fax #:
Mailing Address:
E-Mail:
Contractor:
Phone #:
Fax #:
Mailing Address:
E-Mail:
Contractor Registration Number:
Phone #:
Architect:
Fax #:
Mailing Address:
E-Mail:
B.
TYPEOFWORKORIMPROVEMENT(CheckOne)
NewConstruction
Addition
Alteration
Repair
Relocation
Demolition
Foundation Only
 Plumbing
Electrical
Mechanical
Describe proposed work:
C.DESCRIPTIONOFBUILDINGUSE
RESIDENTIAL
One-Family Dwelling
Two-Family Dwelling
Townhouse
 Carport
Accessory Structure
Deck
 Other - Specify:
NON-RESIDENTIAL
Specific Use:
Use Group:
Change in Use: Yes
No Ifyes,indicateformeruse.:
Maximum Occupancy Load:
Maximum Live Load:
D. ESTIMATED COST OF CONSTRUCTION (reasonable fair market value):
Building:
HVAC:
Plumbing:
Electrical:
TOTAL:
E.BUILDINGDIMENSIONS
Existing Building Area:
.sq. ft.
Number of Stories:
Proposed Building Area:
sq. ft.
Height of Structure Above Grade:
ft.
Total Building Area:
sq. ft.
Area of Largest Floor:
sq. ft.
F.BUILDING/SITE CHARACTERISTICS
Existing,
Number of Residential Dwelling Units:
Proposed
Mechanical: Indicate Type of Heating/Ventilating/Air Conditioning (i.e. electric, gas, oil, etc.):
Water Service (Check one):
Public
Private
Sewer Service (Check one):
Public
Private(Septic Permit#
Distance from Project:
To Well
To Septic Tank
ToDrainField
Fireplace(s): Quantity
Type of Fuel
Type of Vent
Elevators/Escalators/Lifts/Moving walks (Check one):
Yes
No
Yes
Sprinkler System:
No
Yes
Pressure Vessels (e.g. water heater):
äNo
Refrigeration Systems (e.g. air conditioning):
Yes
No
Building Permit Approval
Code Enforcement Officer
Systems Design Engineering, Inc.
1032 James Drive
Leesport, PA 19533
Date
Phone610-916-8522:Fax610-916-8501

Municipality:
County:
Permit No.:
G. HISTORIC DISTRICT
Is the site located within a Historic District?
Yes
No
If construction is proposed within a Historic District, the Municipality may require a certificate of appropriateness.
H.FLOODPLAIN
Is the site located within an identified flood hazard area? (Check one):
Yes
No
N/A
Will any portion of the flood hazard area be developed? (Check one):
Yes
No
N/A
Owner/Agent shall verify that any proposed construction and/or development activity complies with the requirements of the
National Flood Insurance Program and the Pennsylvania Flood Plain Management Act (Act 166-1978), specifically Section 60.3.
Lowest Floor Level:
CONSTRUCTIONPLANS AND SPECIFICATIONS (3-Copies Required)
Construction plans and specifications must be attached illustrating elevations, floorplans, electrical, plumbing, mechanical
layouts, energy code compliance data, design loads and calculations, window and door schedule, typical cross sections, typical
footer and foundation details.
J.SITEPLAN
Site plans must be attached, showing the size and location of the new construction and existing structures on the site and the
structure's distance from the property lines.
K.WORKER'S COMPENSATIONINSURANCE COVERAGE
All applicants are required to submit evidence of Worker's Compensation Insurance Coverage as directed by PA ACT 44.
L.
CERTIFICATIONAND/ORACKNOWLEDGMENT
Application for a permit shall be made by the owner or lessee of the building or structure, or agent of either, or by the registered
design professional employed in connection with the proposed work.
The applicant certifies that all information on this application is correct and the work will be completed in accordance with the
“approved"' construction documents and PA Act 45 (Uniform Construction Code) and any additional approved building code
requirements adopted by the Municipality. Issuance of a permit and approval of construction documents shall not be
construed as authority to violate, cancel or set aside any provisions of the codes or ordinances or the Municipality or any
other governing body. The applicant certifies he/she understands all the applicable codes, ordinances and regulations.
The property owner and applicant assumes the responsibility of locating all property lines, setback lines, easements, rights-of-
way, flood areas, etc. Property owner and applicant shall not construct or erect structures or encroach into the Municipality's
right-of-ways.
Authorized Agent Acknowledgment - I hereby certify that the owner of record authorizes the proposed work and that I have
been authorized by the owner to make this application as an authorized agent and agree to conform to all applicable regulations
set forth by PA ACT 45.
I certify that the code administrator or the code administrator's authorized representative shall have the authority to enter areas
covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit.
Signature of Owner or Authorized Agent
Print Name of Owner or Authorized Agent
Address
Date
Systems Design Engineering, Inc.
1032 James Drive
Leesport, PA 19533
Phone610-916-8522;Fax610-916-8501

PERMIT NO.
PLUMBING PERMIT APPLICATION
Property Owner
Phone No.
Address
Property Location
Subdivision/Development
Plumbing Contractor
Registration No.
Address
Phone No.
NEW
ALTERATION
ADDITION 
REPAIR
Use of Property:
Residential 
Commercial 
Industrial 
TYPEOFEQUIPMENT
NUMBER
Water Closet (Toilet)
Bathtub
Lavatory (Wash Basin)
Shower
NOTE:
Kitchen Sink & Disp.
Dishwasher
This permit is issued contingent upon all
Laundry Tray
work being in compliance with the 2018
IRC or 2018 International Plumbing Code
Clothes Washer
including all supplements and other
Water Heater
applicable Township regulations.
Urinal
Drinking Fountain
Floor Sink or Drain
Applicant certifies that all information given is
correct and that all Township ordinances will be
Slop Sink
complied with in performing the work for which this
Gas Systems: No. Outlets
permit is issued.
Water Piping & Treating Equip.
Waste Interceptor
Vacuum Breakers
Signature of Applicant
Lawn Sprinkler System
Water Service
Sewer
Cesspool
Septic Tank & Pit
Approved
Cost of Improvement
Application Date
Denied
I:\Projects\FORMSIPLUMBINGPERMITAPPLICATION.doc

PERMIT NO.
ELECTRICAL PERMIT APPLICATION
Property Owner
Phone No.
Address
Property Location
Subdivision/Development
Electrical Contractor
Registration No.
Address
Phone No.
NEW
ADDITION 
ALTERATION
REPAIR
Use of Property:
Residential 
Commercial 
Industrial 
TYPEOFEQUIPMENT
NUMBER
Receptacle
Total Outlets
Switch
Lighting
Total Fixtures
Fixtures
Ranges
Clothes Dryer
NOTE:
Water Heater
This permit is issued contingent upon all work
Garbage Disposal
being in compliance with the 2018 IRC or the
Sta. Cook Top
ICC Electrical Code and 2017 NEC including
allsupplementsand
other
Dishwasher
applicable
Township regulations.
Clothes Washer
Space Heater
Sta. Appl. /2 H.P. Max
Applicant certifies that all information given is
Motors:
HP
correct and that all Township ordinances will be
complied with in performing the work for which this
permit is issued.
No. Trans.
Signs:
No. Lamps
Temp. Power  Pole  Undgd.
Signature of Applicant
Service
0-200A
201-400A
New
401-600A
Change
Over 600A
Permit Issuing Fee
Total Fee
Approved
Cost of Improvement
Application Date
Denied
I:\Projects\FORMSIELECTRICALPERMITAPPLICATION.doc

Worker's Compensation Insurance Coverage Information
(UCC Building Permit attachment)
Contractor:
Job Name:
Building Permit #:
A.
The Applicant is:
A contractor within the meaning of the Pennsylvania Workers Compensation Law:
YES
NO
If the answer is “YEs" see Section B, if "NO" complete Section C below
B.
Insurance Information
You MusT submit a copy of your Certificate of Insurance showing Workers
Compensation as a covered Policy. Can be faxed: 610-916-8501; or mailed to:
SystemsDesign Engineering,Inc.
1032JamesDrive
Leesport, PA 19533
C.
Exemption
(please print legibly) do solemnly attest that I will not
employ/hire any other persons for the project for which I am seeking a UcC Building Permit.
After receipt of the building permit if I employ any other persons I will notify this office and
provide proof of worker's compensation coverage within three working days.
I understand that failure to comply will result in a STOp-WORK order and that such order
may not be lifted until proper coverage is obtained, as provided by Section 302(e)(4) of the
Act of June 2, 1915 (P.L. 736), known as The Pennsylvania Worker's Compensation Act,
reenacted and amended June 21, 1939 and amended December 5, 1974 and amended
July 2, 1993. Act 44.
Signature
Subscribedandsworntobeforemethis
day of.
(Signature of Notary Public)

Archived from the Maidencreek Township website. Reproduced unaltered; not an official records repository.