APPENDIX G
SWIMMING POOLS,SPAS AND HOT TUBS
(The provisions contained in this appendix are not mandatory unless specifically referenced in the adopting ordinance.)
SECTIONAG101
mm) deep. This includes in-ground, above-ground and
GENERAL
On-ground swimming pools, hot tubs and spas.
AG101.1General.The provisions of this appendix shall con-
SWIMMING POOL, INDOOR. A swimming pool which is
trol the design and construction of swimming-pools, spas and
totally contained within a structure and surrounded on all four
hot tubs installed in or on the lot of a one- or two-family dwell-
sides by the walls of the enclosing structure.
ing.
SWIMMING POOL, OUTDOOR. Any swimming pool
AG101.2 Pools in flood hazard areas. Pools that are located
which is not an indoor pool.
in flood hazard areas established by Table R301.2(1), includ-
ing above-ground pools, on-ground pools and in-ground pools
that involve placement of fill, shall comply with Sections
SECTIONAG103
AG101.2.1 0r AG101.2.2.
SWIMMING POOLS
Exception: Pools located in riverine flood hazard areas
AG103.1 In-ground pools. In-ground pools shall be designed
which are outside of designated floodways.
and constructed in conformance with ANSINSPI-5 as listed in
AG101.2.1 Pools located in designated floodways. Where
Section AG108..
pools are located in designated floodways, documentation
AG103.2 Above-ground and on-ground pools. Above-
shall be submitted to the building oficial, which demon-
ground and on-ground pools shall be designed and constructed
strates that the construction of the pool will not increase the
in conformance with ANSI/NSPI-4 as listed in Section AG108.
design flood elevation at any point within the jurisdiction.
AG103.3 Pools in flood hazard areas. In flood hazard areas
AG101.2.2 Pools located where floodways have not been
established by Table R301.2(1), pools in coastal high hazard
designated. Where pools are located where design flood
areas shall be designed and constructed in conformance with
elevations are specified but floodways have not been desig-
ASCE 24.
nated, the applicant shall provide a floodway analysis that
demonstrates that the proposed pool will not increase the
design flood elevation more than 1 foot (305 mm) at any
SECTIONAG104
point within the jurisdiction.
SPASANDHOTTUBS
AG104.1 Permanently installed spas and hot tubs. Perma-
nently installed spas and hot tubs shall be designed and con-
SECTIONAG102
structed in conformance with ANSINSPI-3 as listed in Section
DEFINITIONS
AG108.
AG102.1 General. For the purposes of these requirements, the
AG104.2 Portable spas and hot tubs. Portable spas and hot
terms used shall be defined as follows and as set forth in Chap-
tubs shall be designed and constructed in conformance with
ter 2.
ANSI/NSPI-6 as listed in Section AG108.
ABOVE-GROUND/ON-GROUND' POOL: See “Swim-
ming pool."
SECTIONAG105
BARRIER. A fence, wall, building wall or combination
BARRIERREQUIREMENTS
thereof which completely surrounds the swimming pool and
AG105.1 Application. The provisions of this chapter shall
obstructs access to the swimming pool.
control the design of barriers for residential swimming pools.
HOT TUB. See “Swimming pool."
spas and hot tubs. These design controls are.intended to pro-
IN-GROUND POOL. See "Swimming pool."
vide protection. against potential drownings and near-
drownings by restricting access to swimming pools, spas and
RESDENTIAL. That which is situated on the premises of a
hot tubs.
detached one- or two-family dwelling or a one-family town-
house not more than three stories in height.
AG105:2 Outdoor swimming pool. An outdoor swimming
pool, including an in-ground, above-ground or on-ground
SPA, NONPORTABLE. See “Swimming pool"
pool, hot tub or spa shall be surrounded by a barrier which shall
SPA,PORTABLE.A nonpermanent structure intended for
comply with the following:
recreational bathing, in which all controls, water-heating and
1. The top of the barrier shall be at least 48 inches (1219
water-circulating equipment are an integral part of the product.
mm) above grade measured on the side of the barrier
SWIMMING POOL. Any structure intended for swimming
which faces away from the swimming pool. The maxi-
or recreational bathing that contains water over 24 inches (610
mum vertical clearance between grade and the bottom of
APPENDIXG
the barrier shall be 2 inches (51 mm) measured on the
8.2. The gate and barrier shall have no opening larger
side of the barrier which faces away from the swimming
than /, inch (12.7 mm) within 18 inches (457
pool. Where the top of the pool structure is above grade,
mm) of the release mechanism.
such as an above-ground pool, the barrier may be at
9. Where a wall of a dwelling serves as part of the barrier,
ground level, such as the pool structure, or mounted on
one of the following conditions shall be met:
top of the pool structure. Where the barrier is mounted on
top of the pool structure, the maximum.vertical clearance
9.1. The pool shall be equipped with a powered safety
between the top of the pool structure and the bottom of
cover in compliance with ASTM F 1346 or
the barrier shall be 4 inches (102 mm).
9.2. Doors with direct access to the pool through that
2. Openings in the barrier shall not allow passage of a
wall shall be equipped with an alarm which pro-
4-inch-diameter (102 mm) sphere.
duces an audible waming when the door and/or
its screen, if present, are opened. The alarm shall
3. Solid barriers which do not have openings, such as a
be listed and labeled in accordance with UL
masonry or stone wall, shall not contain indentations or
2017. The deactivation switch(es) shall be
protrusions except for normal construction tolerances
located at least 54 inches (1372 mm) above the
and tooled masonry joints.
threshold of the door, or
4. Where the barrier is composed of horizontal and vertical
9.3. Other means .of protection, such as self-closing
members and the.distance between the tops of the hori-
zontal members is less than 45 inches (1143 mm), the
doors with self-latching 'devices, which are
horizontal members shall be located on the swimming
approved by the goveming body, shall be accept-
able as long as the degree of protection afforded
pool side of the fence. Spacing between vertical mem-
is not less than the protection afforded by Item
bers shall not exceed 11/, inches (44 mm) in width.
9.1 or 9.2 described above.
Where there are decorative cutouts within vertical mem-
bers, spacing within the cutouts shall not exceed 1/4
10. Where an above-ground pool structure is used as a bar-
inches (44 mm) in width.
rier or where the barrier is mounted on top of the poo!
structure, and the means of access is a ladder or steps:
5. Where the barrier is composed of horizontal and vertical
members and the distance between the tops of the hori-
10.1. The ladder or steps shall be capable of being
zontal members is 45 inches (1143 mm) or more, spacing
secured, locked or removed to prevent access;
between vertical members shall not exceed 4 inches (102
or
mm). Where there are decorative cutouts within vertical
10.2. The ladder or steps shall be surrounded by a
members, spacing within the cutouts shall not exceed 1/
. barrier which meets the requirements of Sec-
inches (44 mm) in width.
tion AG105.2, Items 1 through 9. When the lad-
6. Maximum mesh size for chain link fences shall be a
der or steps are secured, locked or removed, any
2'/,-inch (57 mm) square unless the fence has slats fas-
opening created shall not allow the passage of a
tened at the top or the bottom which reduce the openings
4-inch-diameter (102 mm) sphere.
to not more than 13/, inches (44 mm).
AG105.3 Indoor swimming pool. Walls surrounding an
7. Where the barrier is composed of diagonal members,
indoor swimming pool shall comply with Section AG105.2,
such as a lattice fence, the maximum opening formed by
Item 9.
the diagonal members shall not be more than 1/, inches
(44 mm).
AG105.4 Prohibited locations. Barriers shall be located to
prohibit permanent structures, equipment or similar objects
8. Access gates shall comply with the requirements of Sec-
tion AG105.2, Items I through 7, and shall be equipped
from being used to climb them.
to accommodate a locking device. Pedestrian access
AG105.5 Barrier exceptions. Spas or hot tubs with a safety
gates shall open outward away from the pool and shall be
cover which complies with ASTM F 1346, as listed in Section
self-closing and have.a self-latching device. Gates other
AG107, shall be exempt from the provisions of this appendix.
than pedestrian access gates shall have a self-latching
device.. Where the release mechanism of the self-latch-
ing device is located less than 54 inches (1372 mm) from
the bottom of the gate, the release mechanism and open-
SECTION AG106
ings shall comply with the following:
ENTRAPMENTPROTECTION FORSWIMMING
POOL AND SPA SUCTION'OUTLETS
8.1. The release mechanism shall be located on the
" pool side of the gate at least 3 inches (76 mm)
AG106.1 General. Suction outlets shall be designed and
below the:topof the gate; and
installed in accordance with ANSVAPSP-7.
TBarierst
he Consumer Product Safety Commission has reported thal drowning is the
I leading causc of accidental death in and around the home for children under
the age of 5 ye ars in California. Arizona, and Florida. Sevenly five percent of the
Hard wired power req'd plus battery backup . . ..
between 1 and 3 years old. Victims had been missing for five minutes or less
.313
wtien they were found in the pool drowned or submerged. Other bodies of water.
Min one detector each story & basemen!
such as fish ponds and fountains, have the same,potential drowning hazards
..F81[313
as pools.
Battery powered OK for remodel
General
IRC
UBC
Compliance req'd for work (>$1.000jrequiring permit or
313
Applies lo all pools or spas >24in deep
-{AG102.1]
(420)
when atterations create an additional bedroom
Fence min 48in high
..F80 [AG105.2]
(421.1#1)
.(313.1
Gap under fence max 2in above grade (4in if concrete]F80 [AG105.2]
(421.1#1)
Bottom max 4in above pool structure when mounted
ontopofpool
-{AG105.2]
(421.1#1)
Max opening size must prevent passage
..F80 [AG105.2]
of4insphere
(421.1#1)
Fig. 81
Difficutt to climb over (no ladder type rails) . . . . . .F80 [AG105.2]
(421.1#1)
Smoke-Dcl
Chain link max 1/sq.in mesh unless flled with slats [AG105.2]
(n/a)
Gate lockable, self-closing, open away from pool .F80 [AG105.2]
(421.1#4)
If latch <54in high: Must be poolside & min
3in below top
..F80 [AG105.2]
(421.1#4)
Top story
No openings >hin within 18in of latch
.{(AG105.2]
(421.1#4)
Doors & screens with direct pool access req. alarm
Ha
audible for 30 seconds throughout house
ad,
[AG105.2]
(421.1#5X
be.
Alarm control min 54in high, must reset
Bedroom
automaticallyExC
[AG105.2]
(421145X
Doors from interior w/self close and release 254in
above floor
{AG105.2]
(421.1#5X
If above ground pool ladder or steps must be
Ist story
lockableorbarrier
[AG105.2]
(421.1#6)
Safety glazing req'd for glass encosing pool
...F80 [308.4]
(2406.4)
Basement
Fig.B0 ·Pool Bamiers
No openlng >'h"
wtthin 18"of gate latch
&latch must be poolsldef
lessthan54"high
nainspecton
Paperwork-special inspcction reports on filc.....119 (109)
Floor finishes that affect stairs or landings mus!
be complete
(109.1
Appliances and futures nust be in iace
Exerior pipe pencrations nust be caull:ed
.(2606
Wood siding and trim min 6in from earth
.323.
Smoke detectors installed and opcralional.
..F61 (313
Any glass
Exterior doors and windows must bc weather tighl . 11102.1.1
Min.
In fence
Building address numbers legble from street ..
..(321
48"
Max. 2
must be safety
from grade ↑
glass or plastic.
Gate' swings
Mak. 4"
Special:inspectlon Repone
outward
opening
S.. reports due before final inspoction
Required
Pilings,dilled plers & caissons
Heat req'd in habitable rooms 68° (7013 above floor
[303.8]
(310.11)
Bolts in concrete
Minoneroom≥120sqft
(310.6.2)
.(304.1)
stpeiatwaim
Habitable rooms exc kitchens min 70sq ft &
Glu-Lam certificate
min dimension 7ft
.{304.2.3]
(310.6.2.3)
Ciling height habitable spaces min '7ft (7ft 6in)
.(305.1)
(310.6.1)
High-strenguh bolting
Kitchens.baths.& hallways min ceilinc hcight 7ft Exc..(305.1]
(310.G.1)
Gft Bin OK in baths ovcr fixurc & fronl clearancc arca . . (305.1]
()
D Ccilinc.liciglitunfinishicd bascments min Grt Bin
EIFS
(305.1)
(n/a)
Municipality: Maidencreek Townshin
County: Berks
Pcrnit No:
ZONING PERMIT APPLICATION
A. LOCATIONAND OWNERSHIP OF PROPOSED WORK OR IMPROVEMENT
Sirect and Numbcr:
Deed Owner(s)Name&Address
Applicant(s)Name&Address
Phone Number
Cell Phone Nunber
Zoning District (as shown on Zoning Map):
Present Tenant:
Residential
B. PRESEN'T USE OF LAND
Commercial
Present use of structure:
Number of Families:
Present Building (Description):
Present Use of Land:
Yes
Is anyportion of theproperty located in a FEMA Flood Plain?
No
Is the site located within a Historic District?
Yes
No
C. PROPOSED WORK OR IMPROVEMENT (check one)
Addition
New Construction
Interior Alteration
ExteriorAlteration
Fence
_Accessory Structure
Deck Cost of Construction $
Sign (Drawing of sign must be submitted with this application)
Change in UsePresent Use
Proposcd Use
Describe proposed work:
Is thc proposed structure or use located in FEMA desighated flood plain _Yes _No
D. PROJECT DIMENSIONS
SETBACKS
PLOT DIMENSIONS
DIMENSIONS
Front
ft.
Frontage
ft.
Width
It.
Side A
Depth
ft.
Depth
Height
Side B
ft.
Area
sq. ft.
ft.
Rear
Irregular plot
ft.
Stories.
SIGNAGE:
Type:
Size:
Number:
sq. ft.
F. APPLICATION
Application is hereby made for a permit to erect or alter a structure which shall be lacaled as shown ou
diagram on reverse side of this sheet and/or to use the premises for the purposes described herewith. The
information which follows, together with local diagram, is made part of this application by the undersigned.
It is understood and agreed by this applicant that any error, misstatement or misrepresentation of material
fact, either with or without intention on the part of this applicant, may cause refusal of this application, or
any change in thc location, size or use of struclure or land made subsequent to the issuance of this permit,
without the approval of the Zoning Officer, shall constitute sufficient grounds for the recvocation of pennit.
Applicant's Signature
Date
Owner. Lessee or authorized agent for owner af suhicct propcrty
F. PLOT PLAN SKETCH
Note: The property owner and applicant assumes the responsibility of locating all property lines
easements, rights-of-way, flood areas, etc. Property owner and applicant shall not construct or erect
G. APPLICATION AND DATES OF ACTION TAKEN (OFFICLAL USE ONLY)
No.
Application approved: Yes
Date
Zoning Official Signature
If denied, Reason for Denial of Application:
NOTE: The applicant has the right to appeal the denial of this application to the Municipality's Z.oning
Hearing Board within 30 days from the date of denial pursuant to procedures set forth in the
Pennsylvania Municipalities Plarning Code, as amended.
Date:
AppealYes _No
Applied to Zoning Hearing Board:
Denied
Date:
Board's Decision:Granted
Order:
Please note: all applications are to be submitted to and all inspcctions are to be called into
Maidencreek Towaship Office at the address and phone number listed below.
Maidencreek Township
Great Valley Consultants
1 Quarry Road
75 Commerce Drive
P.0. Box 319
Wyomissing, PA 19610
Blandon,PA 19510
Phone610-375-8822
Phone (610) 926-4920
Fax 610-375-8977
Fay
(610)926-6314
Municipality:
County:
Pemit No.:
BUILDING CODE PERMIT APPLICATION
A.
LOCATIONOFPROPOSEDWORKORIMPROVEMENT
Site Address:
Tax Parcel #:
Lot No.:
Sub-Division:
Phase:
Section:
Owner:
Phone #:
Fax #:
Mailing Address:
E-Mail:
Contractor:
Phone #:
Fax #:
Mailing Address:
E-Mail:
Contractor Registration Number:
Architect:
Phone #:
Fax #:
Mailing Address:
E-Mail:
B. TYPE OF WORK OR IMPROVEMENT (Check One)
ij New Construction
Addition
C Alteration
Repair
: Demolition
Relocation
U Foundation Only
[: Plumbing
Electrical
Mechanical
Describe proposed work:
C. DESCRIPTION OFBUILDINGUSE
RESIDENTIAL
: One-Fanily Dwelling
Two-FamilyDwelling Townhouse
LI Accessory Structure
Carport
Deck
I Other - Specifir:
NON-RESIDENTIAL
Specific Use:
Use Group:
Change in Use: Yes
No If yes, indicate former use.:
Maximun Occupancy L.oad:
Maximum Live Load:
D. ESTIMATED COST OF CONSTRUCTION (reasonable fair market value):
Building:
Improvement:
Plumbing:
$.
Electrical:
HVAC
TOTAL:
E. BUILDING DIMENSIONS
Existing Building Area:
.sq. ft.
Number of Stories:
Proposed Building Area:
sq. ft.
Height of Structure Above Grade:
ft.
Tolal Building Area:
sq. ft.
Area of Largest Floor:
.sq. ft.
F.
BUILDING/SITE CHARACTERISTICS
Number of Residential Dwelling Units:
Existing.
Proposed
Number of Additional Bedrooms:
Mechanical: Indicate Type of Heating/Ventilating/Air Conditioning (i.e. electric, gazs, oil., etc.):
Water Service (Check one):
Public
Private
Sewer Servicc (Check one):
Public
Private (Septic Permit #
Distance from Project:
To Well
[ To Septic Tank
To Drain Field
Fireplace(s): Quantity
Type of Fuc!
Type of Vent
Elevators/Escalators/Lifts/Moving walks (Check one):
Yes
(I No
Sprinkler Systen:
Yes
No
Pressure Vessels (e.g. water heater):
Yes
No
Refrigeration Systems (e.g. air conditioning):
Il Yes
II No
County:
Municipality:
Permit No.:
G.HISTORICDISTRICT
门Yes
Is the site located within a Historic District?
u No
If construction is proposed within a Historic District, the Municipality muy require cl certijficate of appropriatencss
H. FLOOD PLAIN
ni No
LI Yes
Is the site located within an identified flood hazard area? (Check one):
I N/A
No
UYes
Will auy portion of theflood hazard area bc developed?(Check one):
N/A
Owner/Agent shall verify that any proposed construction and/or development activity complies withi thc requirements of the
National Flood Insurance Program and the Pennsylvania Flood Plain Management Act (Act 166-1978), specifically Section 60.3.
Lowcst Floor Level:
I.
CONSTRUCTION PLANS AND SPECIFICATIONS (3-Copies Required)
Construction plans and specifications must be attached illustrating elevations, floorplarns, electrical, plumbing, mechanical
layouts, energy code compliance data, design loads and calculations, window and doot schedule, typical cross scclions, typical
footer and foundation details.
J. SITE PLAN
Site plans must be attached, showing the size and location of the new construction and existing structures on the site and the
structure's distancc fron the property lines.
K. WORKER'SCOMPENSATIONINSURANCE COVERAGE
All applicants are required to submit evidence of Worker's Compensation Insurance Coverage as directed by PA ACF 44.
L. CERTIFICATIONAND/ORACKNOWLEDGMENT
Application for a permit shall be made by the owner or lessee of the building or structure, or agent of either, or by the registered
cdesign professional employed in connection with the proposed work.
The applicant certifies that all information on this application is corect and the work will be completed in accordance with the
"approved" construiction documents and PA Act 45 (Uniform Construction Code) and any additional approved builcling code
requirements adopted by the Municipality. Issuance of a permit and approval of construction documents shall not be
construed as authority to violate, cancel or set aside any provisions of the codes or ordinances or the Municipality or any
other governing body. The applicant certifies he/she understands all the applicable codes, ordinances and regulations.
The property owner and applicant assumes the responsibility of locating all property lines, setback lines, easements, rights-of-
Way, flood areas, etc. Property owner and applicant shall not construct or erect structures or encroach into the Municipality's
right-of-ways.
Authorized Agent Acknowledgnent - I hereby certify that the owner of rccord authorizes the proposed work and that i have
been authorized by the owner to niake this application as an authorized agent and agree to conform to all applicable regulations
set forth by PA ACT 45.
I certify that the code administrator or the code administrator's authorized representative shall have the authority to enter areas
covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit.
Signature of Owner orAutlorized Agent
Print Nameof Owncror Authorized Agent
Address
Date
OFFICIALUSEONLY
BUILDING Permit Approval:
Code Enforcenent Officer
Date
*Please note: all applications are to be subitted to and all inspections are to be called into Maidencreek Township Office,
1QuarryRoad,POBox319,Blandon,Pa19510610-926-4920.
Maidencreek Township
Great Valley Consultants
1 Quarry Road
75CommerceDrive
PO Box 319
Wyomissing, PA 19610
Blandon,Pa 19510
Phone610-375-8822
Pltone (610)926-4920
Fax(610)926-6314
Fax 610-375-8977
PERMIT NO.
ELECTRICAL PERMIT APPLICATION
Property Owner
Phone No.
Address
Property Location
Subdivision/Development
ElectricalContractor
Registration No.
Address
Phone No.
NEW
ALTERATION
ADDITION
REPAIR
Residential
Commercial
Use of Property:
Industrial
TYPEOFEQUIPMENT
NUMBER
Receptacle
Total Outlets
Switch
Lighting
Total Fixtures
Fixtures
Ranges
Clothes Dryer
Water Heater
NOTE: This permit is issued contingent upon all work
Garbage Disposal
being in compliance with the 2009 IRC or the
2008 NEC including all supplements and other
Sta. Cook Top
applicable Township regulations.
Dishwasher
Clothes Washer
Space Heater
Applicant certifies that all information given is
Sta. Appl. /2 H.P. Max
correct and that all Township ordinances will be
HP
Motors:
complied with in performing the work for which this
permit is issued.
No. Trans.
Signs:
Signature of Applicant
No. Lamps
Temp. Power Pole Undgd.
Service
0-200A
201-400A
New
401-600A
Change
Over 600A
Permit Issuing Fee
Total Fee
Approved
Cost of Improvement
Application Date
Denied
A. [s thc applicant a coutractor within t山c mcaning of thc Pennsylvania Workcr's Compcnsation Law?
Ycs
ONo
If the answer is 'yes", complcte Sections B, C, D and E below as appropriale.
If the answer is "no", complete Sectiou E.
B. INSURANCE INFORMATION
Name of Applicant:
Federal or State Employer Identificatiou Number:
Applicant is a qua lified self-insurer for worker's compeasation.
Check if Certificate is attached.
Name of Worker's Compcnsation Lnsurer:
Worker's Compensatiou Lnasurance Policy Number:
Check if Certificate is attached.
Policy Expiration Date:
C. Is the applicant using any subcoatractor(s) on this project? Yes No
If the answer is “yes", the applicant hereby certifices that any and all subcontractors have preseted proof to the applicant of
insurance under the Peansylvania Worker's Compensation Act
D. EXEMPTION: Complete Section D if the applicant is a contractor claiming exemption from providing worker's compeasation
insurance.
The uadersigned swears or affims that he/she is not required to provide worker's compeusation insurance under thc provisions of
the Pennsylvania Worker's Compensation Law for one of the following reasons,as indicated:
Contractor with no cmployees. Coatractor prohibited by law from employing any individual to perform work pursuant to this
building pemmit unless coatractor provides proof of insurance to the Municipality.
Religious exemptioa under the Worker's Compensation Law.
Subscribed aad sworu to bcfore me this
day of.
Sigaature of Notary Public
My commission expires
(Seal)
E.SIGNATUREREQUIREDFORALLAPPLICANTS.
Siguature of Applicant
Address
County
Municipality of
GreatValleyConsultants
75CommerceDrive
Wyomissing, PA 19610
Phone:610-375-8822
Fax:610-375-8977