Other Township Records
Pool Packet
- Date
- Date unknown
- Type
- Document
- Year
- Undated
- File
- PDF · 5.3 MB
Document text
Machine-extracted from the original — formatting is approximate and there may be recognition errors. Always check the original file above before relying on it. 1,954 words
LTL CONSULTANTS,LTD.·ENGINEERS CODEOFFICIALS ONETOWNCENTREDRIVE POBOX241.OLEY,PA19547 610.987.9290.1.888.987.8886 SWIMMING POOL ELECTRICAL & BARRIER REOUIREMENTS Above Ground Pool Diagram: One inspection will be conducted at the completion of the project If you have any questions call LTL Consultants, Ltd. at 610-987-9290 BEFORE you do the work! *Single grounding type General Use receptacle to supply pool GFCI Receptacles equipment. 125 volt, 15 or 20 amp. If pool wall is less than 48",a barrier is 6 Ft. Min. 6 Ft. Min. required 20 Ft. Max. 20 Ft. Max Both receptacles can be on one post between 6 ft. and 1o ft. from the pool wall. Barrier Requirements: (2018 Swimming Pool and Spa Code) Minimum of 48 inches in height from grade All pedestrian gates must open outward, be self-closing and self-latching Gate latch must be a minimum of 54 inches above grade * When the dwelling is part of the barrier all doors and windows (with a sill height less than 44 inches) must have a UL 2017 alarm installed REVISED2022 ELECTRICAL REQUIREMENTS FOR POOLS GREATER THAN 42INCHES IN DEPTH (2018IRC) Two receptacles are required. Receptacle Number One Located 6 feet minimum from the inside wall of the pool. Provide power to pump motors only. *Single grounding type outlet. (not required to be locking type) GFCI protected. Weather-proof and tamper resistant & weather resistant. Flexible cords cannot exceed 3 feet. If wired directly to pump (no cord or plug), a disconnect must be readily accessible and within sight. Must have weatherproof cover (wet location) when cord is plugged in. Receptacle Number Two Located between 6 and 20 feet from inside wall of pool. GFCI protected and weather-proof. Must be a tamper resistant outlet & weather resistant. Must have weatherproof cover when cords are plugged in. Restricted Space No receptacles may be within 6 feet of the pool wall. All receptacles located within 20 feet of the pool must be GFCI protected. Both receptacles may be on the same circuit. Burial Depth 12" when circuit is maximum 120 volt, GFCI protected at panel and over current protection is 20 amps maximum. Oth.erwise 18" burial depth is required Grounding All electrical equipment associated with the pool shall be grounded. Bonding The pool shell, pool motor/equipment, pool water, and metallic components shall be bonded together with an 8 AWG or larger solid copper bonding conductor. REVISED2022 WP:ISwimmingpools2018IRC.doc LTL CONSULTANTS, LTD - (610-987-9290) PERMIT APPLICATION CHECKLIST Zoning Permit: Submit Application Fee (if applicable for your Township) CHECK PAYABLE TO TOWNSHIP Complete the Zoning/Building Permit Application. Provide a plot plan showing all structures, including sizes, located on the property along with the distance of the structures to each property line. Please note the location ofthe septic system, well, and any easements on the property. Sign the Permit Terms and Conditions Residential Building Permit: Complete the Zoning/Building Permit Application. If electrical, plumbing, and/or mechanical work is being performed, please be sure to complete all appropriate applications. Submit workers compensation insurance for each contractor. Complete the driveway and/or well application (if applicable) Submit Application Fee (if applicable for your Township) CHECK PAYABLE TO TOWNSHIP Provide a plot plan showing all structures, including sizes, located on the property along with the distance of the structures to each property line. Please note the location of the septic system, well, and any easements on the property. Provide two (2) copies of the building plans. Provide proof of EDU from the Sewer Authority or On-Lot Septic permit from the Sewage Enforcement Officer (if applicable) Provide Highway Occupancy Permit from PennDot (if applicable) Provide approval from Water Authority for public water connection (if applicable) Provide Stormwater Management Permit (if applicable) Sign the Permit Terms and Conditions Provide Erosion & Sediment Control Plan approval from Conversation District (if applicable) Additional information/documents may be required depending on the type of construction. CALLBEFORE YOUDIG,MAKEAPA ONE CALL-DiaI811 ZONING/BUILDING PERMIT APPLICATION Please provide a plot plan showing all structures and distances to the property lines Two (2) sets of building plans must be submitted with the application for Residential Projects. Three (3) sets of building plans must be submitted with the application for Commercial Projects. County: Municipality: Site Address: Tax ID#: Owner/Applicant Name: Phone #. Mailing Address: E-Mail: CALL ME WHEN PERMITIS READY Principal Contractor: Phone #: Mailing Address: E-Mail: PA Contractor Registration #: CALL ME WHEN PERMIT IS READY Architect (if applicable): Phone #: Mailing Address: E-Mail: PROPERTY CHARACTERISTICS: Residential Property (Single-Family Dwelling. Two-Fanily Dwelling, Townhouse) Commercial Property -- Specific Use Utilities: Water Service: Public / Private Sewer Service: Public / Private (Circle One) Existing Impervious Area. Sq. Ft. Total Earth Disturbance Sq. Ft. New Impervious Area created: Sg. Ft. A Stormwater Management Perit may be reguired for tne mew impervious area added. Is the property located in a Floodplain or Flood Hazard Area? YES / NO Is the property located in a Historical District?YES / NO Is the property enrolled in the Agricultural Conservation Easement (ACE) program? YES / NO TYPE OF WORK: (check all that apply) New Buiding Renovation Repair Addition Demolition O Sign Deck/Patio Swimming Pool Accessory Structure Fence Other Describe the proposed work Size of Structure: Height of Structure: ESTIMATED COST: (Reasonable fair market value) S (REQUIRED) - OFFICIAL USE ONLY - TOWNSHIP APPLICATIONFEE PAID: CIOCK # Amount s Date: WAmaStersIBUILDINGABUILDING PERMIT APPLICATION PACK ET201RIPERMIT TERMS AND CONDITIONS 011818.doG PERMIT TERMS AND CONDITIONS The Owner/Applicant certifies that all information on this application is correct and the work will be completed in accordance with the approved construction documents, PA Act 45 of 1999 (Uniform Construction Code), Act 247 of 1968 as amended (Municipalities Planning Code), and any additional approved building code requirements adopted by the Municipality. The property Owner/Applicant assumes the responsibility of locating all property lines, setback lines, easements, rights-of-way and flood areas, Issuance ofa permit and approval of construction documents shall not be construed as authority to violate, cance! or set aside any provisions of the codes or ordinances of the Municipality or any other governing body. The Owner/Applicant certifies he/she understands all the applicable codes, ordinances and reguiations and is responsible for all review costs incurred for the proposed project. Building and zoning permits are valid for one year from the date of issue. Construction must be started within 18o days of issue. Permits may be extended only once by making application and paying an extension fee prior to expiration of the original permit. In consideration of the issuance of a permit to the undersigned the Owner/Applicant acknowledges that, in reviewing plans and specifications, in issuing permits, and in periodically inspecting work of the Owner/Applicant, employees of The Municipality and LTL Consultants, Ltd. are only performing their duties to require compliance with the minimum requirements of the applicable Ordinances of The Municipality pursuant to the policy power of The Municipality and are not warranting to the Owner/Applicant or to any third party the quality or adequacy of the design, engineering or construction work of the Owner/Applicant. Owner/Applicant further acknowledges that it will not be possible for The Municipality or LTL Consultants, Ltd. to review every aspect of Owner/Applicant's design and engineering or to inspect every aspect of Owner/Applicant's construction work. Accordingly, neither The Municipality, LTL Cansultants, Ltd. nor any of its elected or engineering or construction work, even if it is alleged that such defects or shortcomings should have been discovered during The Municipality's or LTl, Consultants review ar periodic inspection. Furthernore, the Owner/Applicant agrees to defend, hold harmless and indemnify LTL Consultants, Ltd, The Municipality. its' elected and appointed officials and employees fron and against any and all claims, demands, actions, and causes of action of any ane or more third parties arising out of or relating to The Municipality's ar LTL Consultants, Ltd review or periodic inspection of the Owner/Applicant's design, engineering or construction work, or issuance of a permit or permits, or arising out of or relating to the design, engineering or construction work done by Owner/Applicant pursuant to such permit or pemits. All references in these Terms and Conditions is to Owner/Applicant's employees, agents, independent contractors. subcontractors or any other person or entities performing work pursuant to the issuance of the building or grading permit by The Municipality. Application for a permit shall be made by the Owner of the building or structure, and agent (if different than the owner). I certify the Municipai Code Administrator or LTL Consultants, Ltd, shall have the authority to enter areas covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit. Signature of Property Owner (required) Signature of Authorized Agent (if different than Owner) Printed Name of Property Ownal Print Name of Authorized Agent Address Date Address Last Revised December 27, 2017 REFER TO CHECKLIST TO DETERMINE ADDITIONAL APPLICATION REQUIREMENTS ELECTRICALPERMITAPPLICATION County: Municipality: Site Address: Owner/Applicant Name: Phone #: Mailing Address: E-Mail: CALLMEWHENPERMITISREADY Principal Contractor: Phone #: Mailing Address: E-Mail: PA Contractor Registration # CALLMEWHENPERMITISREADY PROPERTY CHARACTERISTICS: Residential Property (Single-Family Dwelling,Two-FamilyDwelling,Townhouse) Commercial Property - Specific Use Name of Electric Company TYPE OFWORK: New Building Addition Renovation Repair Service (Size: ElectricalJob# Generator (Size Other Phase Amps Voltage Overhead Underground Description of work: Estimated Cost (Reasonable fair market value) $ I hereby certify that the information hereon and herewith is true and correct to the best of my knowledge, and furthermore the property owner has authorized the work. I certify the code administrator or the code administrator's authorized representative shall have the authority to enter areas covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit. Applicant's Signature: Date: PLUMBINGPERMIITAPPLICATION County: Municipality: Site Address: Owner/Applicant Name: Phone #: Mailing Address: E-Mail: CALLMEWHENPERMITISREADY Principal Contractor: Phone #: Mailing Address: E-Mail: PA Contractor Registration # CALLMEWHENPERMITISREADY PROPERTY CHARACTERISTICS: Residential Property (Single-Family Dwelling, Two-Family Dwelling, Townhouse) Commercial Property -- Specific Use TYPEOFWORK: New Building Addition Renovation Repair SewerLateral WaterLateral Other Description of work: Estimated Cost (Reasonable fair market value) $ I hereby certify that the information hereon and herewith is true and correct to the best of my knowledge, and furthermore the property owner has authorized the work. I certify the code administrator or the code administrator's authorized representative shall have the authority to enter areas covered by such permit at any reasonable hour to enforce the provisions of the code(s) applicable to such permit. Applicant's Signature: Date: W:mastersIBUILDINGIBUILDINGPERMITAPPLICATIONPACKET2018\PERMITTERMSANDCONDITIONS011818.doc Workers'Compensation Insurance Coverage Information A. Is the applicant a contractor within the meaning of the Pennsylvania Worker's Compensation Law? YesNo If the answer is “yes, complete Sections B, C, D, and E below as appropriate. If the answer is “no", complete Section E. B. Insurance Information NameofApplicant Federal or State Employer Identification Number Applicant is a qualified self-insurer for workers' compensation Check if Certificate is attached. Name of Workers' Compensation Insurer Workers' Compensation Insurance Policy Number Check if Certificate is attached. PolicyExpiration Date Yes C. Is the applicant using any subcontractor(s) on this project? No If the answer is “yes", the applicant hereby certifies that any and all subcontractors have presented proof to the applicant of insurance under the Pennsylvania Workers' Compensation Act. D. Exemption: Complete Section D if the applicant is a contractor claiming exemption from providing workers'compensation insurance. The undersigned swears or affirms that he/she is not required to provide worker's compensation insurance under the provisions of the Pennsylvania Worker's Compensation Law for one of the following reasons, as indicated: Contractor with no employees. Contractor prohibited by law from employing any individual to perform work pursuant to this building permit unless contractor provides proofof insurance to the Township. Religious exemption under the Workers' Compensation Law. day of , 20 Subscribedand sworn tobefore methis My Commission expires: Signature of Notary Public (Seal) E. Signature required for all applicants Signature of Applicant Address County Municipality of W:mastersiBUILDINGIBUILDINGPERMITAPPLICATIONPACKET/2018IPERMITTERMSANDCONDITIONS011818.doc